18/332.47. INSTALLATIONHexadecimal 02h 4Fh 49h 4Ch 3Ah *1 03hCharacter O I L : *2■Parameters (*1,*2)FRONT/DESK REAR/DESK FRONT / CEILING REAR/CEILINGHexadecimal 30h 31h 32h 33hCharacter 0 1 2 3■Response (Callback)In the period when the command can be acceptedHexadecimal 02h 4Fh 49h 4Ch 3Ah *1 03hCharacter O I L : *2AcceptabilitySECURITY STANDBY(NETWORK)STANDBY(ECO)NO SIGNAL AV MUTE FREEZE× × × ○ ○ ○2.48. FAN CONTROLHexadecimal 02h 4Fh 46h 4Dh 3Ah *1 03hCharacter O F M : *2■Parameters (*1,*2)OFF ON1Hexadecimal 30h 31hCharacter 0 1■Response (Callback)In the period when the command can be acceptedHexadecimal 02h 4Fh 46h 4Dh 3Ah *1 03hCharacter O F M : *2AcceptabilitySECURITY STANDBY(NETWORK)STANDBY(ECO)NO SIGNAL AV MUTE FREEZE× × × ○ ○ ○2.49. LAMP POWERHexadecimal 02h 4Fh 4Ch 50h 3Ah *1 03hCharacter O L P : *2■Parameters (*1,*2)NORMAL AUTO ECO1 ECO2Hexadecimal 31h 32h 33h 34hCharacter 1 2 3 4■Response (Callback)In the period when the command can be acceptedHexadecimal 02h 4Fh 4Ch 50h 3Ah *1 03hCharacter O L P : *2AcceptabilitySECURITY STANDBY(NETWORK)STANDBY(ECO)NO SIGNAL AV MUTE FREEZE× × × ○ ○ ○2.50. POWER MANAGEMENTHexadecimal 02h 4Fh 41h 46h 3Ah *1 *3 03hCharacter O A F : *2 *4■Parameters (*1,*2,*3,*4)OFF 15 30Hexadecimal 30h 30h 31h 35h 33h 30hCharacter 0 0 1 5 3 0■Response (Callback)In the period when the command can be acceptedHexadecimal 02h 4Fh 41h 46h 3Ah *1 *3 03hCharacter O A F : *2 *4AcceptabilitySECURITY STANDBY(NETWORK)STANDBY(ECO)NO SIGNAL AV MUTE FREEZE× × × ○ ○ ○■Note:- When setting “01” to “30”, the setting of Power Magegement is set “Shut down” forcibly..