Panasonic RS-232 Protocolfor LCD Projector35355.22 Gamma Set (OGS)Name Gamma SetSyntax [STX]OGS:p1[ETX]Function This command is to set the GammaParameters Code Description0 Default Data Read1 EEPROM Data ReadResponse [STX]OGS[ETX]Interrupt Processing The Projector must be powered on for this command tobe effective.Examples of Use [STX]OGS[ETX]Notes This command is used for the service and adjustmentof the unit and should only be done by a qualifiedtrained technician.Projector Model to Command CompatibilityModelNumberPT-L711UPT-L711XUPT-L701UPT-L701XUPT-L701SDUPT-L701XSDU PT-L511UPT-L511XUPT-L501UPT-L501XUCommandAcceptanceYes Yes Yes Yes Yes(Yes if Command can be used, No if command cannot be used)