Panasonic RS-232 Protocolfor LCD Projector86865.73 Query Lamp On Condition (Q$S)Name Query Lamp On ConditionSyntax [STX]Q$S[ETX]Function Questions the present condition of the lamp.Parameters NoneResponse [STX]P1[ETX]0 = Standby1 = Lamp On Control Active2 = Lamp On3 = Lamp Off Control ActiveInterrupt Processing The Projector must be powered on for this command tobe effective.Examples of Use [STX]Q$S[ETX]Notes If the lamp is in Standby the projector is powered offIf the Lamp is in Lamp-On Control Active the lamp isturned on and is warming up but has not displaying animage yet. If the lamp is Lamp On the lamp is on anddisplaying an image. If the lamp is Lamp Off ControlActive the unit is in the process of powering off.Projector Model to Command CompatibilityModelNumberPT-L711UPT-L711XUPT-L701UPT-L701XUPT-L701SDUPT-L701XSDU PT-L511UPT-L511XUPT-L501UPT-L501XUCommandAcceptanceYes Yes Yes Yes Yes(Yes if Command can be used, No if command cannot be used)