1-1411.0 1.0 0.97 0.96 0.96 0.95 0.94 0.890.91 0.88 0.87 0.870.87 0.88 0.89-20 -15 -10 -9 -8 -7 -6 -5 -4 -3 -2 -1 0 1 2 65431.00.950.91 0.9260808060401001201403525155 45-15100120-5 -10 50 10-512040608010012040608010015-15-200020406080100120140204060801001201400020406080100120140204060801001201404 6 8 10 12 14 16 18 20 22 24 264 6 8 10 12 14 2016 18 22 244 6 8 10 12 14 2016 18 22 24 26 28 30 4 6 8 10 12 14 2016 18 22 24 26 28 30 32Input coefficient (%) Capacity coefficient (%)Input coefficient (%) Capacity coefficient (%)Cooling capacity ratio (maximum capacity) Heating capacity ratio (maximum capacity)1-7. Capacity Correction Graph According to Temperature ConditionU-200PE1E8 / U-250PE1E8 (For 50 Hz and 60 Hz)Indoor air intake temp (WB)22WB19WB16WB22WB19WB16WBIndoor air intake temp (WB)Outdoor air intake temp (°C DB)16 °C20 °C24 °COutdoor air intake temp (°C DW)24 °C20 °C16 °C125%U-200PE1E8Power consumption ratio (%)Capacity (kW)Rated capacity ratio for cooling121%Power consumption ratio (%)Capacity (kW)Rated capacity ratio for heating123%U-250PE1E8Power consumption ratio (%)Capacity (kW)Rated capacity ratio for cooling125%Power consumption ratio (%)Capacity (kW)Rated capacity ratio for heating1. The graphs " " of the characteristics show the value under the following conditions.Equivalent tubing length : 7.5mDifference of elevation : 0mWind speed : High2. " " marking indicates the maximum capacity / maximum power consumption under the JIS condition.Maximum capacity indicates the maximum value in the parentheses of the specifications (cooling and heating capacity).3. The characteristic of heating capacity excludes the decline of capacity when frosting (including defrost drive).NOTE 11. The graphs " " of the characteristics show the value under the following conditions.Equivalent tubing length : 7.5mDifference of elevation : 0mWind speed : High2. " " marking indicates the rated capacity / rated power consumption under the JIS condition." " marking indicates the maximum capacity / maximum power consumption under the JIS condition.3. The characteristic of heating capacity excludes the decline of capacity when frosting (including defrost drive).NOTE 2To calculate the heating capacity with consideration for frosting/defrosting operation, multiply the heatingcapacity found from the capacity graph by the correction coefficient from the table above.Outdoor unit heating capacity correction coefficient during of frosting/defrosting (RH approximately 85%)Outdoor intake airtemperature°C WBCorrection coefficientIndoor air intake temp (°C WB)Indoor air intake temp (°C WB)