SPECIFICATIONS3Total 0.4A or less (including the current consump-tion of this unit and the connected devices)Allowable throughcurrentPNP open-collector transistor(Photo-coupler isolation)・Maximum source current: 100mA・Applied voltage: 30V DC or less(between output and +V)・Residual voltage:1.5V or less(at 100mA source current)0.4V or less(at 16mA source current)Output(Output 1, Output 2)NPN open-collector transistor(Photo-coupler isolation)・Maximum sink current: 100mA・Applied voltage: 30V DC or less(between output and 0V)・Residual voltage:1.5V or less(at 100mA sink current)0.4V or less(at 16mA sink current)PNP typeModel No.S-LINK side: 0.5mm 2 4-core flat cable 0.6m longUsers' device side: 0.5mm 2 4-core flat cable 0.4m longCable55g approx.WeightMaterial Polycarbonate35 to 85% RH, Storage: 35 to 85% RHAmbient humidity0 to +55℃ (No dew condensation), Storage: -20 to +70℃Ambient temperatureGreen LED (blinks to indicate the synchronizingsignal sent from the S-LINK control unit)TransmissionindicatorOutput 1 indication: Orange LED(lights up when the output 1 is ON)Output 2 indication: Green LED(lights up when the output 2 is ON)Two outputOutput pointOperation indicatorThe output transistor turns on when the S-LINK sends theoutput signal assigned ON through the transmission line.Output operation2.4FAN-inCurrent consumption24V DC±10% (supplied from the S-LINK controlunit or other power supplies)Supply voltage6mA or less(except for connected devices) 12mA or less(except for connected devices)Item SL-CH22 SL-CH22-PNNPN typeTypePlease refer to the 'S-LINK Design Manual' for detailsof the entire S-LINK system.2 channel output unitSL-CH22 or SL-CH22-PNUsers' output device(Electromagnetic valve etc.)ADDRESSON1 2 4 8 163264OFFSL-CH22SENDOUT1:OGI/OSIDENOTUSEDOUT2:GNOUTLINE1● This links two output devices to the S-LINK system.The S-LINK system control the double solenoid valvesthrough the SL-CH22 or the SL-CH22-PN.ADDRESS SETTING6Make sure to operate the switch while the power is offand after taking countermeasures, such as, wriststrap, etc., against electrostatic charge.The address of output 1 is 127 or less. If the addressof output 2 is over 127, the S-LINK system does notwork properly.●●●●●The address of output 1 is given by the sum of all val-ues that corresponding bits are set ON, and the ad-dress of output 2 is made up by adding one to output 1address.The address range is;Output 1: 0 to 126, Output 2: 1 to 127The right-most bit is not assigned (NOT USED).No matter which it is ON or OFF.(e.g.)Output 1 address = 2 + 4 + 32 = 38Output 2 address = (Output 1 address) + 1= 38 + 1 = 39Address set-up switchON1248163264OFFNOTUSED● The MS-SLH (optional) can fix the SL-CH22 andthe SL-CH22-PN.①②Mount the MS-SLH with M4 pan head screws.The tightening torque should be 0.8N・m or less.Press the SL-CH22 or the SL-CH22-PN onto theMS-SLH.Note: M4 pan head screws are not enclosed with MS-SLH. Pleasearrange them separately.2 CHANNEL OUTPUT UNITHOLDER MS-SLH (OPTION)7①②Insert a flathead driver into the gap between themas below.Tilt the flathead screwdriver outward.ADDRESSON1 2 4 8 163264OFFSENDOUT1:OGI/OSIDEOUT2:GNNOTUSEDSL-CH22ADDRESSON1 2 4 8 163264OFFSL-CH22I/OSIDEOUT1:OGOUT2:GNNOTUSEDSENDThank you very much for using Panasonic products.Please read this Instruction Manual carefully andthoroughly for the correct and optimum use of thisproduct. Kindly keep this manual in a convenient placefor quick reference.●●●Never use this product with a device forpersonnel protection.In case of using devices for personnelprotection, use products which meet lawsand standards, such as OSHA, ANSI orIEC etc., for personnel protection appli-cable in each region or country.Before touching this product, remove anyelectrostatic charge that may be presenton your body. There is a danger of thisproduct getting damaged due to the elec-trostatic charge.WARNINGPART DESCRIPTION2ADDRESSON1248163264OFFSL-CH22SENDOUT1:OGI/OSIDENOTUSEDOUT2:GNG (Black)D (White)0V (Blue)+24V (Brown)OUT 2 (Pink / Gray)OUT 1 (Pink)0V (Blue)+24V (Brown)Address set-up switchUse a long-tapered toolof which tip is less than0.8mm wide to togglethe switches, tweezersor the like.Make sure to operate theswitch while the power isoff and after taking coun-termeasures, such as,wrist strap, etc., againstelectrostatic change.Brinks in correspondingto the synchronizing sig-nal sent from the S-LINKcontrol unit・Transmission indicator(Green)Output 1 indication: Orange(Lights up when the output 1 is ON)Output 2 indication: Green(Lights up when the output 2 is ON)Operation indicator(2-color indicator)S-LINK side (LINK SIDE)flat cable of 0.6m long with0.5mm 2 conductor tin-platedUsers' device side (I/OSIDE) flat cable of 0.4mlong with 0.5mm2 conduc-tor tin-platedOUTPUT CIRCUIT DIAGRAMS4● NPN type / SL-CH22The output does not incorporate a short-circuit protectioncircuit. Do not connect it directly to a power supply or acapacitive load.● PNP type / SL-CH22-PNSymbols... ZD1 , ZD2 , ZD3 , ZD4 : Surge absorption zener diodeTr1 , Tr2 : NPN output transistorTr3 , Tr4 : PNP output transistor+24V DC (Brown) (Brown) +24V DC(Pink / Gray) Output 2(Pink) Output 1(Blue) 0V100mA max.100mA max.D (White)G (Black)0V (Blue)Color code Color codeZD1Tr1S-LINK side(LINE SIDE)Internal circuit Uses' device side(I/O SIDE)ZD2Tr2LoadLoadMain circuit+24V DC (Brown) (Brown) +24V DC(Pink / Gray)Output 2(Pink) Output 1(Blue) 0V100mA max.100mA max.D (White)G (Black)0V (Blue)Color code Color codeZD4Tr4ZD3Tr3LoadLoadS-LINK side(LINE SIDE)Internal circuit Uses' device side(I/O SIDE)Main circuitCONNECTING CABLE5Make sure that the power supply is off while wiring.●・Connecting Users' output devicesUsing the socket-branch hook-up connector SL-JK(for cable end) or SL-JK1 (for T-branching) and thesnap male connector SL-CP1 (for 0.08 to 0.2mm 2 ca-ble) or SL-CP2 (for 0.3mm 2 cable) enables to savethe connection work for output devices. However, takecare that there are output devices which can not beconnected.Refer to the instruction manual enclosed with eachconnector for details.●・・Connecting S-LINK lineUse the SL connector tohook up S-LINK side cableof the SL-CH22 or theSL-CH22-PN to the S-LINKfield cable.Colors should be matchedbetween both cable.ADDRESSON1 2 4 8 163264OFFSL-CH22SENDOUT1:OGI/OSIDEOUT2:GNNOTUSEDSL connectorS-LINKfieldColor matchingADDRESSON1 2 4 8 163264OFFSL-CH22SENDOUT1:OGI/OSIDEOUT2:GNNOTUSEDUsers' output device(Beacon etc.)Users' outputdevice(Relay etc.)SL-JK1 (Blue)(For T-branching)SL-CP1 orSL-CP2SL-JK (Light blue)(For terminating) SL-CP1 orSL-CP2INTENDED PRODUCTS FORCE MARKING9● The models listed under ' SPECIFI-CATIONS' come with CE Marking.As for all other models, please contact ouroffice.●3CAUTIONS8● This product has been developed / produced for in-dustrial use only.SL-CH22, SL-CH22-PNSensor & Wire-saving Link System S-LINK2 Channel Output UnitINSTRUCTIONMANUALMJEC-SLCH22 No.0055-62VContact for CEPanasonic Marketing Europe GmbH Panasonic Testing CenterWinsbergring 15, 22525 Hamburg,Germanyhttp://panasonic.net/id/pidsx/global© Panasonic Industrial Devices SUNX Co., Ltd. 2016PRINTED IN JAPANOverseas Sales Division (Head Office)2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, JapanPhone: +81-568-33-7861 FAX: +81-568-33-8591For sales network, please visit our website. |