3211.1 Select the Best Location Install Mono bloc unit at outdoor only. Avoid location where ambient temperature isbelow -20°C. The Mono bloc unit must be installed on a flat,solid surface. A place removed from any heat source or steamwhich may effect the operation of the mono blocunit. A place where air circulation is good. A place where drainage can be easily done. A place where Mono bloc unit’s operation noisewill not cause discomfort to the user. A place where accessible for maintenance. Ensure to keep minimum distance of spaces asillustrated below from wall, ceiling, or otherobstacles. A place where flammable gas leaking might notoccur. A place where the Mono bloc unit’s piping andwiring lengths come within reasonable ranges. If an awning is built over the unit to prevent directsunlight or rain, be careful that he at radiationfrom the condenser is not obstructed. Do not place any obstacles which may cause ashort circuit of the discharged air. Avoid install the Mono bloc unit at a locationwhere suction side may be exposed directly towind. If Mono bloc unit installed near sea, region withhigh content of sulphur or oily location (e.g.machinery oil, etc.), it lifespan maybe shorten. When installing the product in aplace where it will be affected bytyphoon or strong wind such aswind blowing between buildings,including the rooftop of a buildingand a place where there is nobuilding in surroundings, fix theproduct with an overturn preventionwire, etc. (Overturn preventionfitting model number: K-KYZP15C) When connecting solar pump station cablebetween Mono bloc unit and solar pump station,the distance between both apparatuses shall be2 ~ 8 meters and the length of the said cable mustbe shorter than 10 meter.Fail to do so may lead to abnormal operation tothe system.11.2 Mono Bloc Unit InstallationMono bloc unit will become heavy when filled withwater. Please install the unit on a strong concrete floorand consider the weight of the unit and water. Fix Mono bloc unit on the concrete floor with M12anchor bolt at 4 locations. Pull-out strength of these anchor bolts must beabove 15000N.• Compress strength of concrete is above 18MPa {180kgf/cm 2 }Embedded anchor boltAnchor boltFloor slab (concrete)Above20mm80mmGrip anchor boltBroken stoneAnchor bolt 60mm or more300mm ormoreFloorConcreteIllustration of grip type and embedded type anchor bolt