386 Insert firmly the connector of remote controlcable (2) to connector (CON1) in the uppercase circuit board.(Refer to the illustration at below)7 Secure the remote control upper case to thelower case with the tabs provided.Left feeding-out positionLowercaseTop feeding-outpositionRemotecontrolcable (2)NotchesConnector(CON1)Upper caseUpper caseLower caseTabsRightfeeding-out11.4.3.3 Connecting The RemoteControl’s Cable To Mono BlocUnitCAUTIONBe sure to turn off the main power before installing andconnecting the remote control. Otherwise, it will cause theelectrical shock.1 Remove the cabinet front plate.2 Connect the remote control cable with theprovided connector as shown in belowillustration. (Refer wiring diagram for detail.)3 Guide the remote control cable through theclamper, bushing and Cable cover .(Refer illustration “How to connect RemoteControl to Provided Connector” for detail.)4 Reinstall the cabinet front plate afterconnection complete.RemoteControlPCBPlug in firmlyProvidedConnectorRemote ControlConnectorRemove this dummy connectorcap first, before plug inBind the wiredremote controlcable and allpower supplycords to the tubewith band strap(field supply).MAKE SURETHESE CORDSDO NOT TOUCHANY PORTION OFPUMP BODYHow to connect Remote Control to Provided ConnectorClamp the wiredremote control cablewith clamperWired remotecontrol cableConnect the wired remotecontrol cable with theconnector provided here11.5 Checking And Test Cord Run ProceduresWARNINGBe sure to switch off all the power supplies before performing each of the below action.(1) Remove the 5 mounting screwsas shown in the illustration.(2) Slide the cabinet front platedownward to release the pawls.Then, pull it toward front toremove it.Remove The Cabinet Front PlateMounting screwsMountingscrewsRight Cabinet Front Plate 88899(1) Remove the 12 mounting screwsas shown in the illustration.(2) Lift the cabinet top plate9upward to remove it.Remove The Cabinet Top Plate Mounting screwsCabinet Top Plate11.5.1.1 Disposal Of Mono Bloc Unit Drain Water When a Drain elbow is used, please ensure to follow below:o The unit should be placed on a stand which istaller than 50 mm.o Cover the 8 holes (ø20 mm) with Rubber cap(refer to illustration below)o Use a tray (field supply) when necessary todispose the Mono bloc unit drain water.Drain elbowRubber cap × 812 If the unit is used in an area where temperature falls below 0°C for 2 or 3 consecutive days, it is recommendednot to use the Drain elbow and Rubber cap , for the drain water freezes and the fan will not rotate.