-7-n DIP Switch Setting (On the Front Board)Remove the switch cover by removing the screw on the front panel of the Data Converter shown below to expose the DIPswitches.POWERONOFFData Converter WJ-DC ADSWITCHPROTECTERRemove screwRS485 CameraAddressVD2Cable CompCoax. CameraAddress12ON34567890SW201 CH1ONOFFl Camera Address SettingSet the switches (SW201 to SW208, SW221 andSW222) on the board to set the address of the cam-era that is connected to the Camera InputConnector (CAMERA IN) and RS485 Terminal.Up to 1 024 addresses can be set in the system.Refer to the Camera Address Setting on page 86 fordetails.Initially, the addresses shown below are selected atthe factory.CH1(SW201): 1 CH2(SW202): 2CH3(SW203): 3 CH4(SW204): 4CH5(SW205): 5 CH6(SW206): 6CH7(SW207): 7 CH8(SW208): 8RS485-1(SW221): 9 RS485-2(SW222): 10Note: Always set 1st switch to OFF position.Initially, the positions shown below are selected atthe factory.VD2: ONCable Comp: S 500 m (1 600 ft)12ON34SMLVD 2Cable Compl VD2 and Cable Compensation SettingSet the switches (SW211 to SW218) on the board tochoose the most suitable position of the cable-losscompensator and to turn on and off the VD2 (Syncsignal) for the cameras.(1) Set the switches to select VD2 On or Off.Note: Select ON for a camera with VD2 capabil-ity, otherwise select OFF.(2) Set the switches to select the most suitablecable length as shown below.S: Up to 500 m (1 600 ft)M: 500 m (1 600 ft) to 900 m (2 900 ft)L: 900 m (2 900 ft) to 1 200 m (4 000 ft)(When using RG-6/U (5C-2V) or equivalentcable)Caution: Do not select ON position simultane-ously for 3rd and 4th switches.Notes:• The camera addresses set should be the sameas actual (Real) camera numbers of the AD.• After all address settings are completed restart(Power off then on) the unit to initialize the newsettings.