4 Connecting the Unit4.1 Connection ConditionsMaximum cable length varies depending on the power source used for the receiver sideunit and the camera. Refer to the following information when connecting a camera tothe coaxial LAN converter.4.1.1 When using a 1-channel Receiver Side UnitIMPORTANT• Use RG-6/U coaxial cable with a loop resistance of 4 /100 m {328 feet} or less.• When the receiver side unit is powered by PoE, use a PoE camera that consumesno more than 6.5 W. A PoE+ camera cannot be connected.Receiverside unitpowersourceCamerapowersourceCameraside unitEthernetcable lengthReceiverside unitEthernetcable lengthCompatible coaxial cablelengthAC adaptorPoE+ Max. 50 m{164 feet}Max. 100 m{328 feet}Max. 200 m {656 feet}:PoE+ cameraMax. 300 m {984 feet}:Cameras recommended byPanasonic *1PoE Max. 100 m{328 feet}Max. 100 m{328 feet}Max. 300 m {984 feet}: PoEcameraMax. 500 m {1,640 feet}:Cameras recommended byPanasonic *1Externalpower supplyMax. 100 m{328 feet} *3Max. 100 m{328 feet}Max. 2.0 km {6,560 feet}PoEPoE+ Cannot beconnectedCannot beconnectedCannot be connectedPoE *2 Max. 100 m{328 feet}Max. 5 m{16 feet4-27/32 inches}Max. 300 m {984 feet}: PoEcameraMax. 500 m {1,640 feet}:Cameras recommended byPanasonic *1Externalpower supplyMax. 100 m{328 feet} *3Max. 5 m{16 feet4-27/32 inches}Max. 2.0 km {6,560 feet}30 Operating Instructions4 Connecting the Unit