25Parity CheckThis item lets you set the parity check mode for RS-485communication.1. Display the COMMUNICATION menu.2. Select PARITY CHECK by moving the joystick up ordown.3. Select NONE, EVEN or ODD for the parity check bymoving the joystick to the right or left.The initial factory setting is NONE.Note: This setting must be compatible with the peripheralsconnected.Stop BitThis item lets you set the number of stop bits for RS-485communication.1. Display the COMMUNICATION menu.2. Select STOP BIT by moving the joystick up or down.3. Select 1 or 2 for the number of stop bits by moving thejoystick to the right or left.The initial factory setting is 1 bit.Note: This setting must be compatible with the peripheralsconnected.Wait TimeThis item lets you set the waiting time in milliseconds (ms)until the next RS-485 communication retry.1. Display the COMMUNICATION menu.2. Select WAIT TIME by moving the joystick up or down.3. Select OFF, 100, 200, 400 or 1000 ms for the wait timeby moving the joystick to the right or left.The initial factory setting is OFF (No retry).Delay TimeThis item lets you set the minimum delay time from thereception of data to the reply for RS-485 communication.1. Display the COMMUNICATION menu.2. Select DELAY TIME by moving the joystick up or down.3. Select OFF, 20, 40 or 100 ms for the delay time by mov-ing the joystick to the right or left.The initial factory setting is OFF.XON/XOFFThis item lets you set the flow control for RS-485 communi-cation.1. Display the COMMUNICATION menu.2. Select XON/OFF by moving the joystick up or down.3. Select the NOT USE or USE mode by moving the joy-stick to the right or left.The initial factory setting is NOT USE. Communication SetupNote: The COMMUNICATION menu appears when theDATA switch is set to RS-485.Unit AddressThis item lets you set the unit address assigned to the cam-era for RS-485 communication. Be sure to confirm the cam-era unit address before setting up this item.1. Display the COMMUNICATION menu.2. Select UNIT ADDRESS by moving the joystick up ordown.3. Select the unit address assigned to the combinationcamera in the range from 1 to 96 by moving the joystickto the right or left.The initial factory setting is 1.Note: The camera cannot be operated if an address differ-ent from that set on the camera is selected.Baud RateThis item lets you set the baud rate for RS-485 communica-tion.1. Display the COMMUNICATION menu.2. Select BAUD RATE by moving the joystick up or down.3. Select 19200, 9600, 4800 or 2400 bps for the baud rateby moving the joystick to the right or left.The initial factory setting is 19200 bps.Notes:• The data response may be unstable at the baud rate of2400 bps for some functions such as resetting alarms.• This setting must be compatible with the peripheralsconnected.Data BitThis item lets you set the number of data bits for RS-485communication.1. Display the COMMUNICATION menu.2. Select DATA BIT by moving the joystick up or down.3. Select 7 or 8 bits for the number of data bits by movingthe joystick to the right or left.The initial factory setting is 8 bits.Note: This setting must be compatible with the peripheralsconnected.COMMUNICATIONUNIT ADDRESS 1BAUD RATE 19200DATA BIT 8PARITY CHECK NONESTOP BIT 1WAIT TIME OFFDELAY TIME OFFXON/XOFF NOT USE