7. Monitoring and Troubleshooting8700-A2-GB20-40 May 2002 7-11Performance StatisticsPerformance statistics can assist you in determining the duration of specificconditions and provide a historical context for problem detection and analysis.Statistics are maintained for up to 96 15-minute intervals (24 hours).Select a port to view the performance statistics. Port 1 is the default.Use the applicable virtual function keys to page through the intervals and clearstatistics. Select PgUp or PgDn to view more statistics. Select ClrNear or ClrFar to clear the near- and far-end statistics to zero. For DSX-1 and G.703 statistics, select ClrStats to clear all statistics to zero.Limit of six Login IDsreachedAn attempt to enter a newlogin ID was made, and thelimit of six login/passwordcombinations has beenreached.1. Delete anotherlogin/password combination.2. Re-enter the new login ID.No Security Records toDeleteDelete was selected from theAdminister Login screen, andno security records had beendefined. No action is needed. Enter a security record.Password MatchingError – Re-enterPasswordPassword entered in theRe-enter Password field ofthe Administer Logins screendoes not match what wasentered in the Passwordfield. Try again. Contact your systemadministrator to verify yourpassword.Please Wait Command takes longer than5 seconds.Wait until message clears.Test Active A test is running and nohigher priority health andstatus messages exist. Contact service provider iftest initiated by the network. Wait until the other test endsand message clears. Cancel all tests from the Testscreen. Stop the test from the samescreen the test was startedfrom.Table 7-4. Device Messages (2 of 2)Device Message What Message Indicates What To Do