8. Testing8-10 May 2002 8700-A2-GB20-40Ending an Active TestExcept for the Remote Send Line Loopback, a test initiated by the user can beended by the user with the following methods: Test Timeout option – Enable the Test Timeout system option so the unit canautomatically terminate tests, and set the Test Duration (min) option to specifythe amount of time that tests can run before the unit terminates the test. Thedefault is 10 minutes. Refer to Table A-7, System Options, in Appendix A,Configuration Options. Command column – Under the Command column on any test screen,position the cursor at Stop next to the active test and press Enter to stop aspecific test. Abort All Tests menu selection – Select Abort All Tests from the Test menuto stop all tests running on all interfaces. Command Complete appearswhen all tests on all interfaces have been terminated. Network-initiatedloopbacks cannot be stopped from the Test menu.An aborted test may continue to run for a few seconds as the Stop command issent to the remote end and processed.