MTU-M Maintenance Functions6-4 7900-A2-GB20-00March 1998Changing MTU-M Operational Parameters (sysconfig)The sysconfig option on the Maintenance menu is used to display and changeseveral parameters that affect MTU-M operation. Type sys at the maint –>prompt, to display the Operating Parameters screen (values displayed depend onyour current configuration):NOTE:If in the course of making changes you want to start over with the currentsettings, use the read option. This resets the operations parameters back totheir current values.Changes to MTU-M operational parameters do not take effect until you Quit theMTU-M Operations Parameters menu and save your changes.Menu path: Main →Maintenance →sysconfigMTU–M Operations ParametersEEPROM values are: VALIDPolling Range: 2 – 16Polling interval: 10 secondsPoll time-out on 256th’s second 30Initial alarm on/off setting: ONInitial menu on/off setting: ONConsole port baud rate: 9600 baudHit return to continue ...Would you like to modify values? [Y/N]:: YYou must enter password to modify values: ***The following values have been copied to a work buffer andindividual changes will be made to the variables in the work buffer.When finished with changes, enter and you will be asked if you want the changes saved.Hit return to continue ...