Configuration Option TablesA-20 7970-A2-GB20-00August 1999Table A-8. Communication Protocol Options (1 of 2)Node IP AddressPossible Settings: 001.000.000.000 – 223.255.255.255Default Setting: 000.000.000.000Specifies the Node IP address. Node IP Address is only available when the unit is configured as an LTU.Address Field – (001.000.000.000 – 223.255.255.255) – Enter an IP address for thenode. The range for the first byte is 001 to 223, with the exception of 127. The range forthe remaining three bytes is 000 to 255.Clear – Clears the IP address field and sets to all zeros.Node Subnet MaskPossible Settings: 000.000.000.000 – 255.255.255.255Default Setting: 000.000.000.000Specifies the Node Subnet Mask. Node Subnet Mask is only available when the unit is configured as an LTU.Address Field – (000.000.000.000 – 255.255.255.255) – Enter an address for theNode Subnet Mask.Clear – Clears the address field and sets to all zeros.Default Network DestinationPossible Settings: None, COM, DSLDefault Setting: NoneSpecifies where the default management network is connected. For example, if yourdefault network is connected to the COM port, select COM as the default managementnetwork destination.None – No default destination is defined. Data that cannot be routed is discarded.COM – The unit’s COM port is the default network destination. COM is only available when the Port Use option on the Communication PortOptions menu is set to Net Link.DSL – The unit’s DSL port is the default network destination.Communication Port IP AddressPossible Settings: 001.000.000.000 – 223.255.255.255Default Setting: 000.000.000.000Specifies the unit’s Communication Port IP Address when the unit is configured as anetwork communication link. Communication Port IP Address is only used when the Port Use option on theCommunication Port Options menu is set to Net Link. If the COM Port IP addressis not set (000.000.000.000) the node IP address specified by the Node IP Portwill be used.Address Field – (001.000.000.000 – 223.255.255.255) – Enter an IP address for theCommunication Port. The range for the first byte is 001 to 223, with the exception of127. The range for the remaining three bytes is 000 to 255.Clear – Clears the IP address and sets to all zeros.