Commissioning Compact Linear Actuator - LCB12 192-510014 N06 April 2013LCB060(1): Maximum permitted deflection2.2 Fitting / mounting2.2.1. Installation of a single actuatorNoteDanger when transporting long actuators. Because the actuator bends under its ownweight, guiding accuracy may deteriorate significantly. In addition, the shape of the profilemay change and the travel behavior of the (sliding) carriage may be negatively affected.Additional information on transport: (see on page 8)NoteWhen fitting the LCB into your system, please make sure that the deflection station and thesliding carriage are accessible for maintenance! (Provide enough space behind thedeflection station so that the sliding blocks or the sliding carriage can be removed). Take the linear module out of the shipping crate. Place it on the leveled holding points (water level, leveling device). Fix the module (LCB mounting methods) Fasten the connection parts in place. Removing the protective covering (adhesive tape).Note There are two ways to fasten the LCB in place. Mounting with clamping profiles or With T slot bolts/nuts that are guided into the grooves of the aluminum profile.Mounting accessories: see in the catalog section (following the mountinginstructions).NoteThe standard installation position is horizontal with the sliding carriage up.Optionally (after consultation with the manufacturer) a horizontal installation position withthe sliding carriage on the side or at the bottom or vertical installation are also possible.(1)0 500 1000 1500 2000 2500 3000 3500 40000,11,010000,010,0100,01000,0Kraft Fn / NStützabstand SA [mm]0,20 mm0,30 mm0,50 mm1,00 mm2,00 mmKraft / Force Fn / NDistance between mountings SA [mm]0.11.010000.010.0100.01000.00.20 mm0.30 mm0.50 mm1.00 mm2.00 mm