Inverter ContinuousCurrent (A rms)Peak Current(A rms)ContinuousPower (kW)Peak Power(kW)MA3-80-0225 130 225 108 187MA3-80-0325 185 325 154 270MA3-80-0400 225 400 187 325EnvironmentTemperatureOperating Operating temperature is defined as the surrounding air temperature of the drive,when the drive and other equipment adjacent to it is operating at worst caseconditions.-40 °C to +55°C (-40 °F to +131 °F)Note: If the inverter is to be placed in an enclosure, please consult factoryCoolant -40 °C to +55°C (-40 °F to +131 °F)Storage -40 C to +80 C (-40 °F to +176 °F)Shipping -40 C to +80 C (-40 °F to +176 °F)Product Enclosure Rating IP65Altitude Maximum of 2000mHumidity 100% at 40°C (104°F)Atmosphere Non-flammable and non-corrosiveClimatic Conditions Minimum Class 3k6, as defined by EN60721-3-3VibrationStorage and Transport Test Fc of EN60068-2-610Hz<=f<=57Hz sinusoidal 0.075mm amplitude57Hz<=f<=150Hz sinusoidal 1g10 sweep cycles per axis on each of three mutually perpendicular axisOperatingRepetitive Shock TBADrop TBABump TBAVibration TBARandom Vibration TBASafetyOvervoltage Category Overvoltage Category I (numeral defining an impulse withstand level)Pollution Degree Pollution Degree III (dirty air rating)North America/Canada Complies with the requirements of UL508C Type 1