7 • iDSL Port Configuration '6/'$&6$GPLQLVWUDWRUVª5HIHUHQ H*XLGH52 L'6/3RUW,QIRUPDWLRQ3DJHZLQGRZ• (UURUHG6H RQGV2(632HUU6H RQG,GVO3 - An errored second occurs when either (1) the CRC does not matchthe calculated CRC or (2) when the line is linked up but lacking synchronization. Whether 1 error up to 81errors occur within a second, it will still be 1 errored second.• 6HYHUHO\(UURUHG6H RQGV26(632VHY(UU6H RQG,GVO3-AseverelyerroredsecondisdefinedforoneiDSLlineas a second containing more than 82 CRC errors. The SES counter will not be incremented when the boxis incrementing the 8QDYDLODEOH6H RQGV count.• 8QDYDLODEOH6H RQGV28$632XQDYLO6H RQG,GVO3 - Unavailable seconds is an indication of the amount oftime that an iDSL port is activated but not available for data transmission. The UAS counter is incre-mented under the following criteria:1.The port must be activated.2.Once the port is activated and a link-up timer has expired, the UAS counter will be incremented ifthe ports loses sync or does not enter synchronization with the far end of the link.3.Once the port gains link status, the 3092 begins looking for ES and SES.4.Upon receiving 10 consecutive SES or a line down indication, the 3092 will begin reporting UAS.The 3092 will not increment ES or SES during the UAS count.5.The UAS count will stop when 10 consecutive seconds without an SES is detected.)LJXUH+LVWRU\RI1HDU(QG3HUIRUPDQ HZLQGRZClicking on the +LVWRU\ link displays the +LVWRU\RI1HDU(QG3HUIRUPDQ H window (see Figure 18), which dis-plays the cumulative statistics for each of the 15-minute intervals. The most recent 15-minute interval is num-bered 1. The maximum of 15-minute intervals is 96.The +LVWRU\ page collects and records the error history of the port. Interval 1 is the history of the most recent,completed 15-minute interval. The length of each interval is 15 minutes. and records how many ES, SES, andUAS have occurred in the 15 minute intervals. The maximum number of intervals is 96 which is one 24-hourtime period. (15minutes* 96 = 24hours). The +LVWRU\ page always records the last 24 hours error performanceof the port. Information older than 24 hours will not be shown and will be erased. In the example page above,only 5 intervals of information are available, so the page will only show 5 intervals.Port Identification InformationThe 3RUW,GHQWLIL DWLRQ,QIRUPDWLRQ is the same as the &LU XLW,' shown on the main page, it allows users to enteran ID to represent the iDSL port.