7–Removal and ReplacementPower and Cooling Modules7-10 ISR651101-00 CiSR6200 <1> #> admin startPassword : ******iSR6200 <1> (admin) #> fru restoreA list of attributes with formatting and current values will follow.Enter a new value or simply press the ENTER key to accept the current value.If you wish to terminate this process before reaching the end of the listpress 'q' or 'Q' and the ENTER key to do so.Type of restore (0=full, 1=mappings only) [full] 0FRU restore completed.Please reboot the system for configuration to take affect.iSR6200 <1> (admin) #> rebootAre you sure you want to reboot the System (y/n): ySystem will now be rebooted...iSR6200 #>Connection to host lost.The replacement blade should now be operational.Power and Cooling ModulesEach iSR6200 chassis blade has a power and cooling module (PCM), located onthe back side of the chassis. Each PCM consists of one power supply, three fans,and one external status LED.The PCM’s external status LED shows its status: Green = GOOD status, indicating that the PCM is running as expected. Amber = FAULT status, indicating that the PCM has failed.You can remove and replace a failed PCM as described in the following sections: Removing the Failed PCM “Installing a New PCM” on page 7-12