32 © Copyright 2017 QSAN Technology, Inc. All Right Reserved.CLI > tempQuantity of temperature sensors: 11Temperature Sensor Value Status HighCrit HighWarn LowWarn LowCrit---------------------------------------------------------------------------Ctrl 1 Backend Connector 30C OK 75 65 5 0Ctrl 1 Location Bottom Right 42C OK 75 65 5 0Ctrl 1 SAS Wide Port 1 29C OK 75 65 5 0Ctrl 1 SAS Expander 65C OK 95 90 5 0Ctrl 2 Backend Connector 30C OK 75 65 5 0Ctrl 2 Location Bottom Right 41C OK 75 65 5 0Ctrl 2 SAS Wide Port 1 29C OK 75 65 5 0Ctrl 2 SAS Expander 65C OK 95 90 5 0Backplane Location Left 30C OK 70 65 5 0Backplane Location Middle 34C OK 70 65 5 0Backplane Location Right 29C OK 70 65 5 0Table 2-2 Temperature Sensor DescriptionColumn Name DescriptionStatus The status of the temperature sensors: OK: The thermal sensor is present and no error. CRIT: The thermal sensor detected a critical error condition. WARN: The thermal sensor detected a warning error condition. FAIL: The thermal sensor is not accessible.2.6.2. Show Voltage Information (volt)CommandvoltDescriptionShow the voltage sensors information of the system.SyntaxvoltParametersnoneExample