July 7, 2011 7033-277IPage 113100 Wood Stove Series (ACC)RB. Clearances to Combustibles (UL and ULC)BACKWALL / SIDEWALLA BCDEFEFCORNER INSTALLATIONGH *90° OFF TOPUP & OUT CEILINGCLEARANCESTOVE TO CEILINGCLEARANCECDALCOVE TOP VIEWG ABALCOVE SIDE VIEWNOTE: Clearances may only be reduced by meansapproved by the regulatory authority having jurisdictionFire Risk.• Comply with all minimum clearances tocombustibles as specified.• Failure to comply may cause house fire.WARNINGMINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS In Inches & (Millimeters)NOTE: All "A" , "C" and "F" Dimensions are to the inside diameter of the flue collar.A B C D E F G HINSTALLATION: Full Vertical OR Horizontal with Minimum 2 FT Vertical Off Stove TopSINGLE WALL PIPEFlat Top Model 15.25 (387) 11.75 (298) 25.5 (648) 16 (406) 8 (203) 17 (432) 48 (1220) 12 (305)Step-Top Model 12 (305) 8.5 (216) 22 (559) 12.5 (318) 5.5 (140 14.5 (368) 48 (1220) 12 (305)DOUBLE WALL PIPEFlat Top Model 10.5 (267) 6.5 (165) 22 (559) 13 (330) 6.5 (165) 15.5 (394) 48 (1220) 9 (229)Step-Top Model 10 (228) 6 (152) 20.5 (521) 11 (279) 4 (102) 13 (330) 48 (1220) 9 (229)INSTALLATION: 90° Elbow Off Top of Stove Through BackwallSINGLE WALL PIPEFlat Top Model 12 (305) 8.5 (216) 22 (559) 13 (330) 8 (203) 17 (432) 48 (1220) 12 (305)Step-Top Model 10 (254) 6 (152) 20.5 (521) 11 (279) 5.5 (140) 14.5 (368) 48 (1220) 12 (305)DOUBLE WALL PIPEFlat Top Model 8 (203) 4.5 (114) 17.5 (445) 8.5 (216) 6.5 (165) 15.5 (394) 48 (1220) 9 (229)Step-Top Model 10 (254) 6 (152) 20.5 (521) 11 (279) 4 (102) 13 (330) 48 (1220) 9 (229)INSTALLATION: ALCOVE Six inch (6") (152mm) diameter listed Double Wall air insulated connector pipe with UL103 HT* listedfactory-built Class "A" chimney, or a masonry chimney. (Mobile Home must be equipped with a spark arrestor). Maximum depth of Alcoveshall be no more than 48 inches (1220mm) with a minimum height of 48 inches (1220mm) to top of unit, and the referenced clearances.*In Canada must comply with CAN/ULC-S269 M87 for the 650oC Factory-built chimney.DOUBLE WALL PIPEFlat Top Model 11.75 (298) 8.25 (210) 23.5 (597) 14.5 (368) N/A N/A 48 (1220) *Step-Top Model 10 (254) 6.5 (152) 20.5 (521) 11 (279) N/A N/A 48 (1220) ** SEE PIPE MANUFACTURERS CLEARANCES - NOT TESTEDNOTE: Service SpaceIn order to replace the tube channel assembly a clearanceof 19 inches (483mm) is required on the right side of stovein order to remove the tubes with the stove in place.If space is not available, the stove will have to be discon-nected from the chimney to proceed with the tube replace-ment.