49Quadra-Fire • Expression 36 (QV36A-FB) • 2062-900 Rev. S • 11/11Inspect Maintenance TasksDoors, Surroundsand Fronts1. Assess condition of screen and replace as necessary. Recommend addition of screen if one is not present.2. Inspect for scratches, dents or other damage and repair as necessary.3. Verify no obstructions to airflow through the louvers.4. Verify maintenance of proper clearance to combustible household objects.Gasket Seal, GlassAssembly and Glass1. Inspect gasket seal and its condition.2. Inspect glass panels for scratches and nicks that can lead to breakage when exposed to heat.3. Confirm there is no damage to glass or glass frame. Replace as necessary.4. Verify that latches engage properly, clip studs are not stripped, and glass attachment components areintact and operating properly. Replace as necessary.5. Clean glass. Replace glass assembly if severely coated with silicate deposits that cannot be removed.Valve Compartmentand Firebox Top1. Vacuum and wipe out dust, cobwebs, debris or pet hair. Use caution when cleaning these areas. Screwtips that have penetrated the sheet metal are sharp and should be avoided.2. Remove any foreign objects.3. Verify unobstructed air circulation.Logs 1. Inspect for broken, damaged, or missing logs. Replace as necessary.2. Verify correct log placement and no flame impingement causing sooting. Correct as necessary.Firebox 1. Inspect for paint condition, warpage, corrosion or perforation. Sand and repaint as necessary.2. Replace appliance if firebox has been perforated.Burner Ignition andOperation1. Verify burner is properly secured and aligned with pilot or igniter.2. Clean off burner top, inspect for plugged ports, corrosion or deterioration. Replace burner if necessary.3. Replace ember materials with new dime-size and shape pieces. Do not block ports or obstruct lighting paths.4. Check for smooth lighting and ignition carryover to all ports. Verify there is no ignition delay.5. Inspect for lifting or other flame problems.6. Verify air shutter is clear of dust and debris.7. Inspect orifice for soot, dirt or corrosion.8. Verify manifold and inlet pressures. Adjust regulator as required.9. Inspect pilot flame strength. Clean or replace orifice as necessary.10. Inspect thermocouple/thermopile or IPI sensor rod for soot, corrosion and deterioration. Clean with emerycloth or replace as required.11. Verify millivolt output. Replace as necessary.Venting 1. Inspect venting for blockage or obstruction such as bird nests, leaves, etc.2. Confirm that termination cap remains clear and unobstructed by plants, etc.3. Verify that termination cap clearance to subsequent construction (building additions, decks, fences orsheds) has been maintained.4. Inspect for corrosion or separation.5. Verify weather stripping, sealing and flashing remains intact.6. Inspect draft shield to verify it is not bent, damaged or missing.Remote controls 1. Verify operation of remote.2. Replace batteries in remote transmitters and battery-powered receivers.3. Verify batteries have been removed from battery back-up IPI systems to prevent premature battery failureor leaking.Light Bulbs 1. Replace as needed. See Section 10 for instructions.A. Maintenance Tasks