Quadra-Fire • QV36DC-A • 2161-900 Rev. B • 10/08 29Optional AccessoriesOptional fan and remote control kits require that 110-120VAC be wired to the factory installed junction box beforethe fireplace is permanently installed.Wall SwitchPosition the wall switch in the desired position on a wall.Run a maximum of 25 feet (7.8 m) or less length of 18A.W.G. minimum wire and connect it to the fireplace ON/OFF switch pigtailsBLACK S2ONOFFON/OFFSWITCHWHITE T2RED T1THERMOPILEGAS VALVEBLACK S13/16” PIGGYBACK CONNECTORTHERMOCOUPLEREMOTE SWITCHPIGTAILOPTIONAL WALL SWITCH,THERMOSTAT OR REMOTENOTE: IF ANY OF THE ORIGINAL WIREAS SUPPLIED WITH THE APPLIANCEMUST BE REPLACED, IT MUST BEREPLACED WITH TYPE 105° C RATED WIRE.JUNCTION BOXVARIABLE SPEED CONTROLTEMPERATURESENSOR SWITCHWHTGRNBLKBLK110-120 VACBLOWERBLOWER RECEPTACLEBLKBLKBLKBLKWHTGROUNDWHTBLKBLKBLKBLOWER SENSORSWITCH“FAN”RECEPTACLE SPEEDCONTROLStep 8. Wiring the FireplaceNOTE: Electrical wiring must be installed by a licensedelectrician.CAUTION: DISCONNECT REMOTE CONTROLS IFABSENT FOR EXTENDED TIME PERIODS. THIS WILLPREVENT ACCIDENTAL FIREPLACE OPERATION.Appliance Requirements• This appliance DOES NOT require 110-120 VAC tooperate.• A 110-120 VAC circuit for this product must be protectedwith ground-fault circuit-interrupter protection, in compli-ance with the applicable electrical codes, when it is in-stalled in locations such as in bathrooms or near sinks.!Figure 34. Standing Pilot Ignition Wiring Diagram!WARNING: DO NOT CONNECT 110-120VAC TO THE GAS CONTROL VALVE ORTHE APPLIANCE WILL MALFUNCTIONAND THE VALVE WILL BE DESTROYED.WARNING: DO NOT CONNECT 110-120VAC TO THE WALL SWITCH OR THE CON-TROL VALVE WILL BE DESTROYED.CAUTION: LABEL ALL WIRES PRIOR TO DISCONNEC-TION WHEN SERVICING CONTROLS. WIRING ERRORSCAN CAUSE IMPROPER AND DANGEROUS OPERA-TION. VERIFY PROPER OPERATION AFTER SERVICING.Î