Main screen with ambient temperature alarmThe display still shows the dew point (30 °C - 86 °F), but the ambient icon is flashing.Main screen with dew point sensor alarmThe display shows and the dew point icon is flashing.Press the Escape button (14) to reset and restart the dryer manually.3.14 Selection between local, remote or LAN controlSelection between local, remote or LAN controlStarting from the Main screen, press Scroll button (12) until is shown and then press Enter button (13).The actually selected control mode is shown: for local control, for remote control or for LAN control.To change: press Enter button (13) and - if necessary - enter the password (see section Activating passwordprotection). The actually selected control mode is blinking. Use Scroll button (12) to change the control mode.Press Enter button (13) to program the new control mode or press Escape button (14) to cancel.3.15 Calling up/modifying CAN address controlCalling upStarting from the main screen, press the Scroll button (12) until is shown and then press Enter button(13).If necessary enter the password. The next screen shows that the function is ON or OFF. Press the Enter button(13) to change this mode. Use the Scroll buttons (12) to select or and press Enter to program.When this function is ON, use the Scroll buttons up or down (12) to see the node ID.Instruction book28 2920 7103 90