is the offset value that will trigger the alarm. Press Enter button (13): the programmed value startsblinking. To change, use the Scroll buttons (12). Press Enter button (13) to modify and Escape button (14) toreturn to the previous screen.It is also possible to adjust the value when the alarm must disappear again. This is done by adjusting the value. From the screen, press the Scroll buttons (12). Following screen is shown:Press Enter button (13): the programmed value starts blinking. To change, use the Scroll buttons (12). PressEnter button (13) to modify.Press Escape button (14) to exit.3.28 Calling up/modifying the low dew point settingCalling up/modifying the low dew point settingIn protection parameter set Pr. 2, the Low dew point alarm level () and the Low dew point shutdownlevel () can be set. Both values are adjustable between -0.5 °C (31.1 °F) and -0.1 °C (31.82 °F).Starting from the Main screen, press Scroll button (12) until is shown and then press Enter button(13): is shown.Press Enter button (13): the programmed value starts blinking. Use the Scroll buttons (12) to modify.Press Enter button (13) to confirm the new value and press Escape button (12) to return to previous screen.From the screen where is shown, use the Scroll buttons (12) to go to .The value of can be modified in a similar way.Press Escape button (14) to return to the parameter screen.Instruction book36 2920 7103 90