Lost passwords can not be recovered. Save the password carefully.3.25 Selection between flexible alarm and fixed alarmSelecting between flexible alarm and fixed alarmThe dew point alarm can be set in fixed or flexible mode. If set to fixed mode, an alarm will be triggered whenthe dew point exceeds the alarm setting (e.g. 20°C/68 °F). If set to flexible mode, an alarm will be triggeredif the dew point exceeds an offset of the desired dew point (e.g. ambient temperature minus 20 °C/68 °F).Starting from the Main screen, press Scroll button (12) until is shown and then press Enter button(13). The actually selected control mode is shown on the display: for fixed alarm, forflexible alarm.Fixed alarm is selectedTo change: press Enter button (13) . The actually selected alarm mode is blinking. Use Scroll button (12) tochange the alarm mode. Press Enter button (13) to program the new alarm mode. Press Escape button (14) toreturn to the parameter screens.3.26 Calling up/modifying fixed dew point alarm settingCalling up/modifying fixed dew point alarm settingStarting from the Main screen, press Scroll button (12) until is shown and then press Enter button(13): the actual setting of the fixed dew point alarm is shown.Press Enter button (13) to modify this value the temperature unit starts blinking. Use the Scroll buttons (12)to modify the setting.Press Enter button (13) to program the new value. Press Escape button (14) to return to the previous screen.3.27 Calling up/modifying flexible dew point alarm settingCalling up/modifying flexible dew point alarm settingStarting from the Main screen, press Scroll button (12) until is shown and then press Enter button(13). is shown.Press Enter button (13) again. Next screen is shown:Instruction book2920 7103 90 35