15RAM 100 • 1000 • 5500RAMSETwww.ramsetinc.comTerminal # 1 - COMMON:Low voltage common.Terminal # 2 - REv LOOP:Stops the gate from closing. If the gate is open,it holds the gate open. If the gate is closing, itstops and reopens the gate. If the gate is closed,the gate will remain closed. The function can bealtered with Dip Switch “C” 4 (see “Dip SwitchConfiguration”). Used with loop detectors, photoeyes, safety edges…etc. Becomes active with aclosed contact to common.Terminal # 3 - CLOSE:Closes the gate. Used with three button stationsor pushbuttons. Becomes active with a closedcontact to common.Terminal # 4 - FIREBOX:Opens the gate. Used with fire department keyswitches & controls. Opens with closed contactto common. Closes immediately when closedcontact on common is removed.Terminal # 5 - EXIT:Opens the gate. Used with loop detectors, photoeyes, keypads, phone entry systems, three-but-ton stations…etc. Becomes active with a closedcontact to common.Terminal # 6 - PhANTOM:Keeps the gate open when the open limit switchis activated. Used with loop detectors. Becomesactive with a closed contact to common.Terminal # 7 - RADIO:Operation depends on dip switch “C” 3 (See “DipSwitch Configuration”). Used with an RF receiveror pushbutton. Becomes active with a closedcontact to common.Terminal # 8 - EDGE:When triggered the gate will stop. The gate willremain stopped until the detector is cleared. Oncethe detector is cleared, the operator will resumenormal operation. If triggered twice beforereaching a limit switch, the alarm will sound for6 minutes and the control board will not acceptany commands. After the 6 minutes the 24 VDC isremoved from the alarm connection and the boardresets to normal operation.Terminal # 9 and 10 - LIMIT 1 & LIMIT 2:Direction depends on Dip Switch “C” 7 (See “DipSwitch Configuration”). Stops the motor frommoving in one direction. These wires are preset infactory and should not be moved. Becomes activewith a closed contact to common.Terminal # 11 and 12 - COMMON:Low voltage common.Terminal # 13 - +24 vAC:Provides 24 VAC for peripheral accessories.Terminal # 14 and 15 - MAG (-) & MAG (+):Supplies 24 VDC to a Magnetic Lock when thegate is closing or closed. If gate is opening oropened, then no power is supplied. Leave openif not used.Terminal # 16 - M BRAkE:Used ONLY on the Ram 50 Operator. If whilethe gate is closed someone or something tries tomanually open the gate without a proper signal(keypad, exit loop, radio signal…), the motor willlock up for 6 minutes. After the 6 minutes, theoperator will then secure close the gate.Terminal # 17 and 18 - MOTOR 1 & MOTOR 2:Supplies power to the motor. Direction dependson Dip Switch “C” 7 (see “Dip Switch Configura-tion”). These wires are preset and connected inthe factory and should not be moved.Terminal # 19 and 20 - AC hOT & NEUTRAL:110 VAC or 220 VAC to power the operator.Voltage is predetermined at factory and cannot bechanged by the installer or technician.TERMINAL STRIP CONNECTIONS