COPYRIGHT © 2015 RED.COM, INCR E D 4 K B R O A D C A S T M O D U L E O P E R AT I O N G U I D E 955-0072, REV-E | 19ERR (ERROR) LINK STATUSSYMPTOMThe 4K Broadcast menu shows that the Link Status for either the Camera or Module is “Err” (error).POTENTIAL RESOLUTION Reboot the BRAIN. Remove the 4K Broadcast Module and the adaptor module. Check the module connectors. If the connectorshave dust or debris, clean the connectors. If any connectors are damaged, contact your Bomb Squadrepresentative. Use a different adaptor module.VIDEO DOES NOT DISPLAY CORRECTLYSYMPTOMS Image does not display. Image freezes. Quadrants are not in sync.POTENTIAL RESOLUTIONS Go to Menu > Settings > Display > 4K Broadcast and select Video Reset. This resets the video connection. Go to Menu > Settings > Project > Format > UHD and re-select the Resolution. Then select Set Format.NO TIMECODE IN VIA 4K BROADCAST MODULESYMPTOMS Camera does not receive timecode signal when a timecode generator is connected to the 4K Broadcast Module. The TC indicator does not illuminate green.POTENTIAL RESOLUTIONSEnsure that each of the following has the same frame rate: Sensor Frame Rate Project Time Base Timecode generator05 TROUBLESHOOT YOUR4K BROAdCAST MOdULE