Page | 13 Ascento 37 Export St Lytton QLD PH: 1800 807 604 | VSRM Inverter Contant Pressure Pumps | V2016.12INSTALLATION CHECKLIST: MUST BE FILLED IN FOR WARRANTY TO APPLYInstaller Name ____________________________ Qualification:________________Phone Number:_________________Wiring of Power Outlet if applicable completed by Electrician _________________________Licence No: _________________Installation Address: ________________________________________________________________________________Tick the boxes as the item is completed/correct, put n/a if not applicable;[ ] I have checked that the VSRM is the correct size/power for its intended use, and is being used for appropriate purpose forwhich it is intended, according to these instructions.[ ] The Power Circuit the VSRM is connected to is RCD (Safety Switch) Protected and I have checked that it is of suitable sizefor the kW/Amps of the motor of the pump.[ ] A Y-Strainer or Pre-filter is installed in the suction pipe to prevent particles entering the pump[ ] A quality Check-Valve is fitted in the suction pipe near the inlet of the pump[ ] All swarf has been removed from the tank after cutting openings etc.[ ] Barrel Unions are fitted on the pipe connections for easy removal & replacement[ ] A Ball Valve or Gate Valve is fitted to the suction pipe (the pipe from tank to pump) and to the discharge also[ ] Pipe is sized appropriately for the application (suitable diameter and length)[ ] The installation is constructed so the pump can be easily removed or replaced.[ ] For Connections to Town Water: The pump is installed in accordance with National & Local Plumbing Regulations[ ] The Electrical Supply cable is plugged into a Power Outlet that is in accordance with the current standard of ElectricalSafety Regulations AS/NZS 3000 ā or the pump has been wired directly to the power circuit by a Licenced Electrician.[ ] The Pump has been primed (filled with water) started, tested, and operates correctly.[ ] The pipes and connections and the barrel-union on the pump, and toilet cisterns and irrigation (if connected) have beenchecked for leaks.[ ] The pump is protected from sunlight and rain and from interference by children or vandals, with a suitable vented pump-cover or enclosure.[ ] The Owner/Resident has been shown how to re-prime and re-set the pump (re-fill the pump with water if it runs dry) and ifit is a suction-lift application (not recommended) the Owner/Resident has been shown how to check if the suction pipe has lostprime and how to re-prime the suction pipe.[ ] The Owner/Resident has been shown how to reset the pressure settings and explained that if the pressure is set too highthe pump will never turn off (run continuously) and explained that the higher the pressure is set to the more electricity andwater is used.[ ] If the pump starts & stops or runs continuously I have checked the Pressure settings and if that does not resolve the issue Ihave checked for leaks by performing a Pressure-test on ALL the pipework including the SUCTION pipework.Signed by the Installer: _____________________________ Date Installed:_____/_____/________