MODULAR SAFETY INTEGRATED CONTROLLER MOSAIC92 8540780 • 30/03/2016 • Rev.26english Two output test signals are mandatory. Each output OUT TEST can be connected toonly one input S-MAT (it is not allowed parallel connection of 2 inputs). The function block S-MAT can not be used with 2-wire components and terminationresistance.Output test: This is used to select which test output signals are to be sent to the s-matcontact. This additional control permits detection and management of any short-circuitsbetween the lines. To enable this control, the test output signals must be configured(amongst those available). Test signals are mandatory.Test at start-up: If selected this enables the test at start-up of the external component.This test is performed by pressing and releasing the safety mat to run a completefunction test and enable the output. This test is only requested at machine start-up (whenthe unit is switched on).Filter (ms): This is used to filter the signals coming from the external contacts. The filtercan be configured to between 3 and 250 ms and eliminates any bouncing on thecontacts. The length of the filter affects the calculation of the unit's total response time.Enable Error Out: If selected reports a fault detected by the function block.Item description: This allows a description of the component's function to be entered. Thetext is displayed in the top part of the symbol.SWITCH function block verifies the input statusof a pushbutton or switch (NOT SAFETYSWITCHES). If the pushbutton is pressed theoutput is 1 (TRUE). Otherwise, the output is 0(FALSE).ParametersManual reset: If selected this enables the requestto reset each time the device is activated.Otherwise, enabling of the output directly followsthe input conditions.There are two types of reset: Manual andMonitored. When Manual is selected the systemonly verifies the signal's transition from 0 to 1.If Monitored is selected the double transition from 0 to 1 and then back to 0 is verified.t = 250mst1 > 250mst2 = 250ms WARNING: If the Manual Reset is active, a consecutive Input have to be used.Example : Input 1 is used for the fuctional block, then Input 2 have to be used forthe Reset Input.