Regency® E18 Gas Fireplace Insert 5SAFETY LABELThis is a copy of the label that accompanies each Regency ® Gas Insert. We haveprinted a copy of the contents here for your review. The safety label is located on thefront inside base of the unit visible when the bottom louver is open.Note: Regency® units are constantly being improved. Check the label on theunit and if there is a difference, the label on the unit is the correct one.Please note that with the addition of thermostat control and outsidecombustion air supply, this unit is approved for bedroom installations.For the State of Massachusetts, installation and repair must be done by a plumberor gasfi tter licensed in the Commonwealth of Massachusetts.For the State of Massachusetts, fl exible connectors shall not exceed 36 inchesin length.For the State of Massachusetts, the appliances individual manual shut-off mustbe a t-handle type valve.The State of Massachusetts requires the installation of a carbon monoxide alarmin accordance with NFPA 720 and a CO alarm with battery back up in the sameroom where the gas appliance is installed.DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ETIQUETTESerial No. / No de serie4001172415415Min. supply pressure 5" WC (1.25kPa)Low Setting Man. pressure 1.6" WC (0.40kPa)Max. Manifold pressure 3.5" WC (0.87kPa)Orifice size 44 DMS (2.64mm)Minimum input 15,000 Btu/h (4.40kW)Altitude 0-4500ft (0-610m)Maximum input 21,600 Btu/h (6.33kW)919-179aNATURAL GAS FIREPLACE INSERT: MODEL E18-NGPROPANE FIREPLACE INSERT: MODEL E18-LP12" WC (2.99 kPa)6.4" WC (1.59 kPa)10" WC (2.49 kPa)55 DMS (1.6mm)17,000 Btu/h (4.98kW)0-4500ft (0-610m)20,500 Btu/h (6.01kW)FPI Fireplace Products International Ltd.Delta BC, CANADAMADE IN CANADA / FABRIQUE AU CANADAModel: E18-NG Model: E18-LPFactory Equipped For Altitude 0-4500ft. (0- m)1370Duplicate Serial numberThis appliance must be installed in accordance with local codes, if any; if none,follow the National Fuel Gas Code, ANSI Z223.1, or Natural Gas and PropaneInstallation Code, CSA B149.1.This appliance must be installed in accordance with the Standard CAN/CSA Z240MH, Mobile Housing, in Canada, or with the Manufactured Home Constructionand Safety Standard, Title 24 CFR, Part 3280, in the United States, or when such astandard is not applicable, ANSI/NCSBCS A225.1/NFPA 501A, ManufacturedHome Installations Standard or ANSI A119.2 ou NFPA 501C Standard forRecreational VehiclesThis appliance is only for use with the type of gas indicated on the rating plate andmay be installed in an aftermarket, permanently located, manufactured (mobile)home where not prohibited by local codes. See owner's manual for details.WARNING. This fireplace has been converted for use with a gas fireplace insertonly and cannot be used for burning wood or solid fuels unless all original partshave been replaced, and the fireplace re-approved by the authority havingjurisdiction.Installer l'appareil selon les codes ou règlements locaux, ou, en l'absence de telsrèglements, selon les codes d'installation ANSI Z223.1, National Fuel Gas Codeou CSA-B149.1 en vigueur.Installer l'appareil selon la norme CAN/CSA-Z240, Série MM, Maison mobiles ouCAN/CSA-Z240 VC, Véhicules de camping, ou la norme 24 CFR Part 3280,Manufactured Home Construction and Safety Standard. Si ces normes ne sontpas pertinentes, utilisez la norme ANSI/NCSBCS A225.1/NFPA 501A,Manufactured Home Installations Standard, ou ANSI A119.2 ou NFPA 501CStandard for Recreational Vehicles.AVERTISSEMENT : Ce foyer a été converti pour utilisation avec un foyer au gazencastrable et ne peut être utiliser pour brûler du bois ou d'autres combustiblessolides à moins que toutes les pièces d'origine aient été remplacées et que lefoyer ait été approuvé de nouveau par l'autorité compétente.For use with glass doors certified with the appliance onlyThis vented gas fireplace heater is not for use with air filters.Ne pas utiliser de filtre à air avec ce foyer au gaz à évacuation.Cet appareil doit être utilize uniquement avec le type de gaz indiqué sur la plaquesignalétique. Cet appareil peut être installé dans une maison préfabriquée oumobile (É.-U. seulement) installée à demeure si les règlements locaux lepermettent. Voir la notice de l'utilisateur pour plus de renseignements. Cetappareil ne peut pas être utilisé avec d'autres gaz sauf si une trousse deconversion certifiée est fournie.Pour utilisation uniquement avec les portes en verre certifiées avec l'appareilMinimum Clearances to Combustibles:Min. Mantel Height A 17-7/8"(453mm)Min. Ceiling B 37-7/8"(961mm)DSide wall E 6" (152mm)Max. Mantel Depth F 9" (229mm)Height37-1/2"(953mm)Degagement Minimum Des MateriauxCombustibles:Listed:Certified for/Certifi e pour:Tested to:CANADA and U.S.A.VENTED GAS FIREPLACE HEATER/ FOYER AU GAZ À ÉVACUATIONéCAN/CGA-2.17-M91(R2009)Electrical supply / Électrique 115VAC, 2.5 A, 60Hz,Less than 10A Fan Part # 911-071Min. supply pressureLow Setting Man. pressureMax. Manifold pressureOrifice sizeMinimum inputAltitudeMaximum inputFactory Equipped For Altitude 0-4500ft. (0-1370m)FDEBAVENTED GAS FIREPLACE HEATER - NOT FOR USE WITHSOLID FUELS. / NE PASUTILISER AVEC DUCOMBUSTIBLE SOLIDE.FOYER AU GAZ À ÉVACUATION -Conforms to: ANSI Z21.88a-2012Certified to: CSA 2.33a-2012