16 | Regency ® L234-10 Direct Vent Gas Insert|16installationCONVERSION FROM NG TO LP919-465 11.25.141L234CONVERSION KIT #537-969 FROM NG TO LPLP Conversion Kit Contains:Qty. Part # Description1 910-037 LP Pilot Orifi ce1 904-163 Orifi ce #541 904-529 5/32" Allen Key1 910-582 Stepper Motor1 918-590 LP Conversion Decal1 908-528 Red Propane Label1 919-465 Instruction SheetTHIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER, IF IN DOUBT DO NOT DO THIS CONVERSION!!LP Conversion Instructions1. Shut off gas and electrical supply to the unit.2. Remove the faceplate.3. Remove the safety screen and glass door- see manual for detailed instructions.4. Remove the logs if installed.5. Remove the brick panels if installed.6. Remove the burner by undoing the 3 screws.Burner Removed7. Remove the burner tray by undoing the 4screws.Burner Tray Removed8. Remove burner orifice with a 1/2" wrenchand discard.9. Install the new LP burner orifice stamped#54 and tighten.10. Pull off the pilot cap to expose the pilotorifice.11. Unscrew the pilot orifice with the suppliedallen key and replace it with the LP pilot orificein the kit and re-install the pilot cap.12. Remove NG stepper motor by removing 3screws in locations shown below–replacewith LP stepper motor, secure in placewith 3 screws.Remove NG Stepper motor andreplace with LP Stepper motor13. Check for gas leaks with a proper soapysolution or leak detector.14. Check inlet and outlet pressures. Referto "Gas Pipe Pressure Testing" section ofthe manual.15. Attach the label "This unit has been con-verted to LP" near or on top of the serial #decal.15. Replace yellow "NG" label with red "LP"label.16. Reverse Steps 8 - 1.NOTE: before re-installng burner, check theLP aeration settings.17. Check operation of flame control.18. Check for proper flame appearance andglow on logs.