8 | LRI4E / HRI4E Direct Vent Gas Insert|8requirements5.08: Modifications to NFPA-54, Chapter 10(2) Revise 10.8.3 by adding the following additional requirements:(a) For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part forresidential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less thanseven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shallbe satisfied:1. INSTALLATION OF CARBON MONOXIDE DETECTORS. At the time of installation of the side wall horizontal vented gas fueledequipment, the installing plumber or gasfitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up isinstalled on the floor level where the gas equipment is to be installed. In addition, the installing plumber or gasfitter shall observe that a batteryoperated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structureserved by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services ofqualified licensed professionals for the installation of hard wired carbon monoxide detectorsa. In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the hard wired carbonmonoxide detector with alarm and battery back-up may be installed on the next adjacent floor level.b. In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period ofthirty (30) days to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbonmonoxide detector with an alarm shall be installed.2. APPROVED CARBON MONOXIDE DETECTORS. Each carbon monoxide detector as required in accordance with the above provisionsshall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified.3. SIGNAGE. A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight(8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. Thesign shall read, in print size no less than one-half (1/2) inch in size, "GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALLOBSTRUCTIONS".4. INSPECTION. The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installationunless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR5.08(2)(a)1 through 4.(b) EXEMPTIONS: The following equipment is exempt from 248 CMR 5.08(2)(a)1 through 4:1. The equipment listed in Chapter 10 entitled "Equipment Not Required To Be Vented" in the most current edition of NFPA 54 as adopted bythe Board; and2. Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate from the dwelling, building orstructure used in whole or in part for residential purposes.(c) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM PROVIDED. When the manufacturer of ProductApproved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, theinstructions provided by the manufacturer for installation of the equipment and the venting system shall include:1. Detailed instructions for the installation of the venting system design or the venting system components; and2. A complete parts list for the venting system design or venting system.(d) MANUFACTURER REQUIREMENTS - GAS EQUIPMENT VENTING SYSTEM NOT PROVIDED. When the manufacturer of aProduct Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the flue gases, but identifies"special venting systems", the following requirements shall be satisfied by the manufacturer:1. The referenced "special venting system" instructions shall be included with the appliance or equipment installation instructions; and2. The "special venting systems" shall be Product Approved by the Board, and the instructions for that system shall include a parts list anddetailed installation instructions.(e) A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions,all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipmentat the completion ofthe installation.MA Code - CO Detector(for the State of Massachusetts only)