Regency ® PG36D Gas Log Fireplace 11INSTALLATIONFLUEINGRegency® Direct Vent System (Flex)Horizontal Terminations OnlyThese flueing systems, in combination with the PG36D Room Sealed Gas Fireplace, have been tested and listed as a Direct Vent type flue systemby the Australian Gas Association. The location of the termination cap must conform to the requirements in the Flue Terminal Locations diagram insection "Exterior Flue Termination Locations."Regency ® Direct Vent (Flex) System Termination Kit (Part # 946-515) includes all the parts needed to install the PG36D with a maximumrun of 1200mm.1) 175mm dia. flexible liner (1200mm length)2) 100mm dia. flexible liner (1200mm length)3) spring spacers (4)4) thimble (2)5) AstroCap termination cap (1)6) screws (12)7) tube of Mill Pac (1)8) plated screws (8)9) screws #8 x 1-1/2" Drill Point, StainlessSteel (4)If longer runs are needed, the Regency®Direct Vent system (Flex) # 946-516 includesall the parts needed to install the PG36D witha maximum 3.0m run.1) 175mm dia. flexible liner (3.0m length)2) 100mm dia. flexible liner (3.0m length)3) spring spacers (7)4) thimble (2)5) AstroCap termination cap (1)6) screws (12)7) tube of Mill Pac (1)8) plated screws (8)9) screws #8 x 1-1/2" Drill Point, StainlessSteel (4)Notes:1) Liner sections should be continuous without any joints or seams.2) Only Flex pipe purchased from Regency® may be used for Flex installations.3) If you are installing the PG36D into a Regency® Mantel Kit, use the minimum horizontal vent height (centre-line of 1029mm). Rememberto include the mantel base in your calculations and to maintain the 32mm clearance (38mm with Flex) to the underside of the manteltop.6-7/8"(173mm)dia. Flue pipe4" (102mm)dia. flue pipespring spacerTermination Cap(Part# 946-578/P)AstroCap(patented)Wall Thimble