Regency ® PG36D Gas Log Fireplace8152m m Side W all127m m51m mM antellegM antellegP36DFireplaceAllow able m antellegprojection.76m m38m mINSTALLATIONNote: 40-1/2" (1029mm) is the minimumheight for both flex termination orSimpson Dura-Vent flueing.5) BARCELONA FRAMING NOTE: Ifinstalling the optional Barcelona front, anon-combustible material 12" (305mm)above the unit and 6"(153mm) on eachside must be used. The Barcelona Frontalso requires steel stud framing aboveand on each side of the unit. See Diagram3 in section "Combustible Mantels" andDiagram 1 in section "Locating Your GasFireplace."BARCELONA INSTALLATION NOTE:When installing the PG36D with theBarcelona Trim into a Regency ® Style 3Mantel Kit, ensure that the combustiblemantel sides and top are 3/8" backfrom the front face of the fireplace. SeeDiagram 2 in section "CombustibleMantels."Note: The unit does not have to becompletely enclosed in a chase. Theclearance on top of the unit is 0" tothe standoffs so combustible buildingmaterials can be laid directly on topof the standoffs. You must maintain1-1/2" (38mm) clearance from theflue to combustible materials for flex(1-1/4" for Simpson Dura-Vent ).6) Use steel studs for framing where the1-1/2" (38mm) clearance from the flue tocombustible material cannot be maintained,e.g. front top header.Diagram 2MANTEL LEGCLEARANCESCombustible mantel leg clearances as perdiagram below:FRAMING ANDFINISHING1) Determine the total thickness of facingmaterial (e.g. drywall plus ceramic tiles) toallow the finished surface to be flush withthe front of the unit. Total facing thicknesscan vary from 1/2" (13mm) to 1-1/4" (32mm)thick.Maximum38mmprojectionat 51mmminimumclearance.3) For exterior walls, insulate the enclosure tothe same degree as the rest of the house,apply vapour barrier and drywall, as perlocal installation codes. (Do not insulatethe fireplace itself.)4) The top of the unit must not be closer than32" (813mm) to the ceiling.Install Side Nailing Strips, Top Facing Support,and Top Standoffs before unit is slipped intoposition. See section "Unit Assembly Priorto Installation" for assembly details.2) Frame in the enclosure for the unit withframing material. The framed opening is37-1/4" high x 36-1/4" wide x 17-3/8" deep(946mm high x 921mm wide x 432mmdeep).Framing DimensionsA B C D36-1/4" 37-1/4" 17-3/8" 46-1/2"*921mm 946mm 432mm 1182mm** 'D' is Minimum height to combustible ma-terials including the Minimum 2-1/2" (64mm)Top clearance to the Horizontal Flue, see flueclearances in section "Clearances."