INSTALLATIONRegency® L676S Direct Vent Gas Fireplace44SAFETY LABELThis is a copy of the label that accompanieseach L676S-NG1 and L676S-LP1 Direct VentGas Fireplace. We have printed a copy of thecontents here for your review.NOTE: Regency® units are constantly beingimproved. Check the label on the unit and ifthere is a difference, the label on the unit isthe correct one.COPY OF SAFETY DECALFor the State of Massachusetts, installationand repair must be done by a plumber orgasfi tter licensed in the Commonwealth ofMassachusetts.For the State of Massachusetts, fl exibleconnectors shall not exceed 36 inches inlength.For the State of Massachusetts, the appli-ances individual manual shut-off must be at-handle type valve.The State of Massachusetts requires theinstallation of a carbon monoxide alarm inaccordance with NFPA 720 and a CO alarmwith battery back up in the same room wherethe gas appliance is installed.DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ETIQUETTEListed: VENTED GAS FIREPLACE HEATERTested to: ANSI Z21.88a-2007/CAN/CGA-2.17-M91Certified for / Certifiée pour: CANADA AND U.S.A.WN # 16074CSA 2.33a-2007,Serial No. / No de serie342`NATURAL GAS FIREPLACE: MODEL L676S-NG1Factory Equipped For Altitude 0-4500ft. (0-1372m)Min. Supply Pressure 5“ WC (1.25 kpa)Low Setting Man. Pressure 1.6" WC (0.39 kpa)Max. Manifold Pressure 3.5" WC (0.87 kpa)Orifice Size #37 DMSMinimum Input 19,500 Btu/h (5.71 )Maximum Input 29,000 Btu/h (8.49 kW)kW342Model/Modele:L676S-NG1Model/Modele:L676S-LP1918-760PROPANE GAS FIREPLACE: MODEL L676S-LP1Factory Equipped For Altitude 0-4500ft. (0-1372m)Min. Supply Pressure 12" WC (2.98 kpa)Low Setting Man. Pressure 6.4" WC (1.59 kpa)Max. Manifold Pressure 10" WC (2.49 kpa)Orifice Size #53 DMSMinimum Input 21,000 Btu/h (6.15 kW)Maximum Input 26,000 Btu/h (7.61 kW)FPI Fireplace Products International Ltd., Delta BC, CANADAMADE IN CANADA / FABRIQUE AU CANADAMinimum Clearances to Combustibles from Fireplace OpeningSide Walls *A 14-3/4" (375mm)Ceiling B 52" (813mm)Min. Mantel Height C 16-1/2" (419mm)Max. Mantel Depth **D 13” (330mm)Alcove Width E 84" (2134mm)Alcove Depth F 36" (914mm)Finished Floor G 3” (76mm)VENTED GAS FIREPLACE HEATERThis appliance must be installed in accordance with the manufacturer’s installationinstructions and with local codes, if any; if none, follow the current ANSI Z223.1 inthe USA or the current CAN 1-B149 in Canada.This vented gas fireplace heater is not for use with air filters.For Manufactured Home Installation: This Direct Vent System Appliance must beinstalled in accordance with the manufacturer's installation instructions andManufactured Home Construction and Safety Standard Title 24 CFR, Part 3280, or thecurrent Standard for Fire Safety Criteria for Manufactured Home Installation, Sites, andCommunities ANSI/NFPA 501A, and with CAN/CSA Z240 MH Mobile Home Standard inCanada.This appliance is only for use with the type of gas indicated on the rating plate and maybe installed in an aftermarket, permanently located, manufactured (mobile) homewhere not prohibited by local codes. See owner's manual for details. This appliance isnot convertible for use with other gases, unless a certified kit is used (Kit #526-969).Certified for use with Heat Wave (Kit #946-556).For use with glass doors certified with the appliance only.Electrical Supply: 6.0 VDCNOT FOR USE WITH SOLID FUELDEFABCRefer to Manual for complete Clearance Details* Alcove side wall must have a min. of 14-3/4” (375mm) clearance on one side.** Mantel depth taken at 26-1/2” (673mm) from front facing.G