Regency P33SE Gas Fireplace 9INSTALLATIONThis includes:1) Clocking the appliance to ensure the correctfiring rate (rate noted on label), after burningappliance for 15 minutes.2) If required, adjusting the primary air to ensurethat the flame does not carbon. First allowthe unit to burn for 15-20 min. to stabilize.CAUTION: Any alteration to the product thatcauses sooting or carboning that resultsin damage is not the responsibility of themanufacturer.LOCATING YOURGAS FIREPLACEB) Flat on Wall CornerC) Recessed into Wall/AlcoveD) CornerDiagram 11) When selecting a location for your fireplace,ensure that the clearances are met.2) The appliance must be installed on a flat,solid, continuous surface For example awood, metal or concrete floor or in a raised (onthe wall) application. The appliance must beinstalled on a metal or wood panel extendingthe full width and depth of the appliance.3) The P33E Gas Fireplace can be installed ina recessed position or framed out into theroom as in A, B, C and D. See Diagram 1.A) Flat on Wall7) Test Gas Pressure (Refer to "Gas Pipe Pres-sure Testing" section).8) Install 4 AA batteries in the battery pack.Batteries must be installed to operate theburner switch.9) Install standard and optional features. Referto the following sections:a) Optional Stainless Steel ReflectivePanelsb) Glass Crystals or Optional CeramicStonesc) Optional Firebox Base Pebblesd) Remote Control or Wall Thermostate) Optional Fan Assemblyf) Faceplate10) Wall Mounted ON/OFF Switch:Use the toggle wall switch supplied with themanual package. Use of a “decor” switchcauses higher resistance which is a problemon gas fireplaces.11) Final check.Before leaving this unit with the customer, theinstaller must ensure that the appliance is firingcorrectly and operation fully explained tocustomer.INSTALLATIONCHECKLIST1) Locate appliancea) Room location (Refer to "Locating YourGas fireplace" section)b) Clearances to Combustibles (Refer to"Clearances" section)c) Mantle Clearances (Refer to "MantelClearances" section)d) Framing & Finishing Requirements(Refer to "Framing & Finishing" section)e) Venting Requirements (Refer to "Venting"section)2) Assemble Top and Side Standoffs (Refer to"Unit Assembly Prior to Installation).3) Slide unit into place.4) Install vent (Refer to "Venting Arrangement"sections).5) Make gas connections (Refer to "Gas LineInstallation section).6) Test the pilot (Refer to "Pilot Adjustment"section).4) This appliance is Listed for bedroominstallations when used with a listed MillivoltThermostat. Some areas may have furtherrequirements, check local codes beforeinstallation.5) The P33E Gas Fireplace is approved foralcove installations, see "Clearances" sectionfor details.6) We recommend that you plan your installationon paper using exact measurements forclearances and floor protection beforeactually installing this appliance. Have anauthorized inspector, dealer, or installerreview your plans before installation.Note: For vent terminations refer to"Exterior Vent Termination Locations"section.