LRI3E / HRI3E Direct Vent Gas Insert | 15| 15installation1. Detach the Flue Connector Plate from the unit by removing theConnector Plate Screws and sliding the Flue Connector Plate forwardand off the unit.NOTE: Flue Plate Connector Gasketmust not be damaged or removed.Care must be taken to ensure that thisgasket remains intact to prevent lueleakage.5. When the Flue Connector Plate is close to the front of the unit, engagethe Flue Connector Screws and carefully tighten the Flue ConnectorPlate the inal amount.** Make sure the Rear Tab connects into the slot in the Flue ConnectorPlate. Failure to do so will result in lue gas leakage and degrade theoperation of the unit ** (See diagram below of location.)The Flue connection is complete when the Flue Connector Plate is fullyforward and the Rear Tabs are fully engaged.6. Remove the Flue Connector Tool and store for future use.2. Attach the Flue Liners onto the Flue Connector Plate using non RTVtype sealant, then fasten with 3 screws.See the section in this manual on Venting installation.3. Position the unit in front of the ireplace opening, start the Flue Connec-tor Plate into the Flue Connector Plate Guides.Flue Connector Slide ToolTab connected correctlyFlue Connector PlateConnector plate screws4. Use the Flue Connector Slide Tool to slowly pull the Flue ConnectorPlate forward as you move the Insert rearward into the Fireplace Chase.FLUE / VENT INSTALLATIONWARNING:Failure to position the parts in accordance with these diagrams or failureto use only parts speciically approved with this appliance may result inproperty damage or personal injury.Connecting the Vent LinersIntake LinerExhaust Linerlue connecterplate