LRI3E / HRI3E Direct Vent Gas Insert | 7| 7safety decalThis is a copy of the labels that accompany each LRI3E Gas Insert. Wehave printed a copy of the contents here for your review.NOTE: Regency units are constantly being improved. Check the label onthe unit and if there is a difference, the label on the unit is the correct one.NATURAL GAS FIREPLACE INSERT: MODEL LRI3E-NGFactory Equipped For Altitude 0-4500ft. (0-1370m)Min. supply pressure 5.5" WC (1.37 kpa)Low Setting Man. pressure 1.0" WC (0.25 kpa)Max. Manifold pressure 3.8" WC (0.95 kpa)Orifice size #45 DMSMinimum input 10,500 Btu/h (3.08 kW)Maximum input 21,000 Btu/h (6.15 kW)PROPANE GAS FIREPLACE INSERT: MODEL LRI3E-LPFactory Equipped For Altitude 0-4500ft. (0-1370m)Min. supply pressure 11" WC (2.73 kpa)Low Setting Man. pressure 2.0" WC (0.50 kpa)Max. Manifold pressure 10.6" WC (2.64 kpa)Orifice size #55 DMSMinimum input 10,500 Btu/h (3.08 kW)Maximum input 21,000 Btu/h (6.15 kW)Model/Modèle:LRI3E-NG919-693Part #: 919-693Colour: Black on grey except what is highlighted is printed redSize: (File at 100%) 6.495"W x 8.66" HMaterial: 2 ml silver matt polyester (DPM SMS)Aug 08/2016: Created draftStart serial sequence @ 000001DO NOT REMOVE THIS LABEL /NE PAS ENLEVER CETTE ÉTIQUETTESerial No. / No de série449449Duplicate Serial number/Copie No de sérieListed: VENTED GAS FIREPLACE HEATER/ FOYER AU GAZ À ÉVACUATIONCertified for/Certifi e pour : CANADA and U.S.A.éTested to: CAN/CGA-2.17-M91(R2009)Conforms to: ANSI Z21.88-2014Certified to: CSA 2.33-2014VENTED GAS FIREPLACE HEATER - NOT FOR USE WITH SOLID FUELS.FOYER AU GAZ À ÉVACUATION - NE PAS UTILISER AVEC UN COMBUSTIBLE SOLIDE.Model/Modèle:LRI3E- LPÉ ÉQUIP EN USINE POUR GAZ PROPANEMODÈLE LRI3E-LPÉ ÉQUIP EN USINE POUR GAZ NATURELMODÈLE LRI3E-NGPression d'alimentation minimumPression de sortie (manifold) - bassePression de sortie (manifold) - max.Taille de l'orificeD bit calorifique minimuméD bit calorifique maximuméMin. Hearth Depth /Prof. min. âtre D 12” (305mm)Min. Hearth Width/Largeur min. âtre E 36” (914mm)Max. Mantle Depth/Prof. max. manteau G 12" (305mm)Mantel Clearances / Dégagements manteauRegency Fireplace ProductsDelta BC, CANADASide wall /mur latéral A 6” (152mm)Ceiling/Plafond B 60” (1524mm)Mantel/Manteau C 38” (965mm)Min. Alcove Width/Largeur min. alcôve K 54" (1372mm)Max. Alcove Depth/Prof. max. alcôve L 36” (914mm)MADE IN CANADA /FABRIQUÉ AU CANADAMinimum Clearances to Combustiblesfrom Insert/Dégagements min. combustiblesThis appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1, or Natural Gas andPropane Installation Code, CSA B149.1.This appliance is only for use with the type of gas indicated on the rating plate.This appliance is not convertible for use with other gases unless a certified kit is used.This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured(mobile) home where not prohibited by local codes. See owner's manual for detailsWARNING. This fireplace has been converted for use with a gas fireplace insert only and cannot be used for burning wood or solid fuels unless all originalparts have been replaced, and the fireplace re-approved by the authority having jurisdiction.Cet appareil doit être installé conformément aux codes et règlements locaux, ou, en l'absence de tels règlements, conformément au National Fuel GasCode ANSI Z223.1, ou au CSA-B149.1 en vigueur.Cet appareil doit être utilisé uniquement avec le type de gaz indiqué sur la plaque signalétique. Cet appareil peut être installé dans une maisonpréfabriquée ou mobile (É.-U. seulement) installée à demeure si les règlements locaux le permettent. Voir la notice de l'utilisateur pour plus derenseignements. Cet appareil ne peut pas être utilisé avec d'autres gaz sauf si une trousse de conversion certifiée est fournie.Cet appareil n'est pas convertible pour une utilisation avec d'autres gaz, sauf si un kit certifié est utilisé.AVERTISSEMENT : Ce foyer a été converti pour être utilisé avec un foyer au gaz encastrable et ne peut être utilisé pour brûler du bois ou d'autrescombustibles solides à moins que toutes les pièces d'origine aient été remises en place et que le foyer ait été homologué de nouveau par une autoritécompétente.This vented gas fireplace heater is not for use with air filters. Ne pas utiliser de filtre à air avec ce foyer au gaz à évacuation.For use with glass doors certified with the appliance only. Pour utilisation uniquement avec les portes en verre certifiées avec l'appareil.For use only with barrier (Part # 716-010) Follow installation instructions. Pour utilisation uniquement avec l’écran(Pièce n°716-010)Suivre les consignes d'installation.4001172Pression d'alimentation minimumPression de sortie (manifold) - bassePression de sortie (manifold) - max.Taille de l'orificeD bit calorifique minimuméD bit calorifique maximuméElectrical supply / Alimentation électrique 115VAC, 2.5 A, 60Hz, Less than 10A Fan Part # 911-207/Pièce ventilateurACBEKDLGFor the State of Massachusetts, installation and repair must be done by a plumber or gasitter licensed in the Commonwealth ofMassachusetts.For the State of Massachusetts, lexible connectors shall not exceed 36 inches in length.For the State of Massachusetts, the appliances individual manual shut-off must be a t-handle type valve.The State of Massachusetts requires the installation of a carbon monoxide alarm in accordance with NFPA 720 and a CO alarm withbattery back up in the same room where the gas appliance is installed.COPY OF SAFETY LABEL LRI3E