LRI6E / HRI6E Direct Vent Gas Insert | 23| 23installationHRI6E OPTIONAL LOG SET INSTALLATION919-350b 07.18.16Ensure unit is cooled to room temperature and remove glass door.1. HRI4E Unit only.Remove burner (see manual for instructions).Remove existing pilot shield by removing 2 screws.Install pilot shield provided with Log Set using 2 screws fromprevious pilot shield. Reinstall burner.Read the instructions below carefully and refer to the images. If the logs are broken do not use the unit until they are replaced. Brokenlogs can interfere with pilot operation.Improper positioning of the logs and glass crystals may create carbon build-up and can alter the unit's performance which is not cov-ered under warranty.*For Touch Ups: Dark Brown paint is included.Note: This Log installation is for NG units only.1 Rear Centre Log2 Centre Right Front Angled Log Piece3 Right Forked Upright Log4 Left Angled Upright Log5 Left Angled Cross Log6 Right Front Angled Log Piece7 Centre Left Front Angled Log PieceRear Log Bracket (HRI6E/HRI4E units)Pilot shield (HRI4E units only)Lava Rock and Embers1234 765Glass/Beads quantities with Log installationHRI4E 6 lbsHRI6E 9 lbsNote: If glass previously installed - remove 2lbs to equal above quantity.2. Both HRI4E & HRI6E Units.Sweep glass aside from pilot covers (if already installed) to installRear Log Bracket, clip the front edge of the rear bracket on to rear ofthe burner as shown below.IMPORTANT: After the Rear Log Brackets are installed glass crystalsmust be reapplied. Glass crystals should not be higher then the bottomof the pilot screen cover as shown in diagram 3. Pilot area needs to beclear to allow proper ignition as shown in diagram 3.Rear Log BracketsNew Pilot Shield - HRI4E Only Reapply glass crystals on burner as shown below.Do not apply any glass crystals over the pilot/burnerscreen cover. This must remain free and clear andis required for air flow.Pilot AreaRear Log Brackets Pilot AreaNOTE: HRI4E shown above. The HRI6 pilot (not shown) is located onthe left hand side.Pilot/Burner Screen CoverPilot/burner screen coverDiagram 3Diagram 2Diagram 11HRI6E / HRI4EOPTIONAL LOG SET INSTALLATION