29Electric schemePH - output for the output modulation main heat source type 0…10V,mod B – modules for additional heating circuits (optional),L N PE - mains supply 230V~,FU – fuse,CPU – control,H1-P – direct (nonadjustable) circuit water pump,H2-P – adjustable circuit water pump,H3-P – adjustable circuit water pump,H2-M – mixing valve actuator,H3-M – mixing valve actuator,Z-P – DHW tank loading water pump,C-P – DHW circulating pump,S-P – solar pump with PWM input,OUT-A, OUT-B, OUT-C – universal voltage outputs,HC – heat source (volt-free contact).Controller electrical connections diagram, where:H1-S – direct circuit / hydraulic coupling water temperature sensor type CT-10,H2-S – water temperature sensor of adjustable circuit type CT-10,H3-S – water temperature sensor of adjustable circuit type CT-10,DHW – temperature sensor of water inside DHW tank type CT-10,T1, T2, T3 – room thermostats for independent heat circuits,PWM – output for the regulation of the solar pump type PWM,SL- solar sensor for DHW tank type CT-6,SH – solar collector sensor type CT6-W,H4-S – universal temperature sensor, e.g. for measuring temperature of afireplace with water jacket type CT-10,WS – weather temperature sensor type CT6-P,H5-S – universal temperature sensor, e.g. for measuring temperature of heatbuffer type CT-10,