Salus SS912ZB Installation & Quick Start Manual
Version 3Installation/Quick Start Guide: Slim Door/Window Sensor (SS912ZB)Visit www.salusinc.com for the User ManualIn the Box Tools Needed Note:Additional equipment may be requireddue to building construction or materials,or other radio interference that mayreduce the radio range.Sensor with battery(1x CR2, 3V Lithium)Magnet Mounting Kit Installation/Quick-start Guide#1 Phillips ScrewdriverPAIRING INSTRUCTIONS• Follow your system’s instructions to prepare to add devices to the system.• Remove the face plate from the Sensor and pull the battery tab to startthe pairing process.• When the Sensor is detected and added to the system, proceed to theSensor installation.INSTALLATION INSTRUCTION• Identify the location for the Sensor and Magnet, orienting the flat end ofthe Sensor and Magnet parallel to each other as shown, and theMagnet on the right side (side with indicator). The preferred locationfor the Sensor is on the door or window casing on the handle side ofthe door or window, with the Magnet on the door or window as close aspossible to the Sensor. Proper installation may require mounting theSensor and Magnet inverted or rotated from the orientation shown.• Position the Sensor at the desired location and screw into positionusing the screws provided. If screws are not appropriate, use the includedadhesive pad by first removing the brown backing of the adhesive padand attaching it to the Sensor bottom. Make sure to properly align thetamper switch opening. Then remove the white/red paper tape and pressthe Sensor to the desired location. (For UL installations, the unit mustbe mounted with screws.)• Open the Magnet case, position the Magnet at the desired location andattach to the door or window with the screws, replacing the Magnet coverwhen done. If screws are not appropriate, use the adhesive pad by firstremoving the brown backing and attaching it to the Magnet bottom. Thenremove the white/red paper tape and press the Magnet to the desiredlocation. (For UL installations, the unit must be mounted with screws.)Depending on the depth of the door or window in the frame, the includedspacer may be required to raise the Magnet above the surface of the door orwindow. Use the longer screws to attach the Magnet with the spacer.• Open and close the door to verify that the Sensor is working properly, andthe Sensor or Magnet does not interfere with the opening and closing of thedoor.REPLACING THE BATTERY(Use only Duracell DL-CR2, Rayovac RL-CR2, Energizer EL1CR2, or GP Batteries GPCR2 batteries)• Slide the Sensor face plate up and lift it from the Sensor body.• Press a finger on the positive end of the battery and lift to remove the batteryfrom the Sensor.• Insert a new battery into the Sensor, observing the proper polarity.• Position the Sensor face plate over the Sensor body and slide the face plate ontothe Body.FACTORY RESETTING THE SENSOR• Remove the face plate from the Sensor.• Remove the battery.• Press and hold the tamper switch while re-inserting the battery.• Release the tamper switch when the LED lights on the front of the Sensor. TheSensor is reset to factory defaults and will respond to pairing requests.• After pairing, replace the face plate on the Sensor.LED INDICATIONSSolid at power up: Initializing, checking for Factory Reset3 flashes then pause: Searching for network to join |
Related manuals for Salus SS912ZB
Salus SS881ZB Installation And Quick Start Manual
Salus SS881ZB Quick Install Manual
Salus SPE600 Installation Manual
Salus OS600 Installation Manual
Salus OS600 Installation Manual
Salus OS600 Installation Manual
Salus OS600 Installation Manual
Salus SC428ZW Installation & User Manual
Salus SW600 Quick Manual
Salus SW600 Quick Manual
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine