21ENGLISHSetting an indoor unit installation option (suitable for the condition of each installation location)1. Check whether power is supplied or not.- When the indoor unit is not plugged in, there should be additional power supply in the indoor unit.2. The panel(display ) should be connected to an indoor unit to receive option.3. Set the installation option according to the installation condition of an air conditioner.- The default setting of an indoor unit installation option is “02000-100000-200000-300000”.- Individual control of a remote controller(SEG20) is the function that controls an indoor unit individually when there is morethan one indoor unit.- No need to assign SEG3, 6, 8, 9, 10, 11, 14, 22, 23, 24 which are non applicable. Even though those segments are set, they willbe ignored.- If you set the applicable segments with numbers other than the indiciated, the initial setting will be maintained.4. Set the indoor unit option by wireless remote controller.Option No. : 02XXXX-1XXXXX-2XXXXX-3XXXXXOption SEG1 SEG2 SEG3 SEG4 SEG5 SEG6Explanation PAGE MODERESERVEDUse of externaltemperaturesensorUse of centralcontrolRESERVEDIndicationand DetailsIndication Details Indication Details Indication Details Indication Details0 2 0 Disuse 0 Disuse1 Use 1 UseOption SEG7 SEG8 SEG9 SEG10 SEG11 SEG12Explanation PAGERESERVED RESERVED RESERVED RESERVED RESERVEDIndicationand DetailsIndication Details1Option SEG13 SEG14 SEG15 SEG16 SEG17 SEG18Explanation PAGE Use of external control Setting the output ofexternal control S-Plasma ion Buzzer control Number of hoursusing filterIndicationand DetailsIndication Details Indication Details Indication Details Indication Details Indication Details Indication Details20 DisuseSlave(disableLevelcontrol*)0 Thermoon 0 Disuse 0 Use ofbuzzer 2 1000Hour1 On/Offcontrol2 Offcontrol3Windowon/offcontrol4 DisuseMaster(enableLevelcontrol*)1 Operationon 1 Use 1Nonuse ofbuzzer6 2000Hour5 On/Offcontrol6 Offcontrol7Windowon/offcontrolSEG18 is applied in case of strong wind.CAUTION