28Connecting the assembly cablet Connect the power cable to the auxiliary circuit breaker. If every pole fails to connect tothe power supply, it must be incorporated in a wire with a contact opening of ≥3mm.Connecting the cable1 Extend the assembly cable if necessary.2 Open the front grille.3 Remove the screw securing the connector cover.4 Pass the assembly cable through the rear of the indoor unit and connect theassembly cable to terminals as seen in the picture.5 Pass the other end of the cable through the 65mm hole in the wall.6 Close the connector cover, tightening the screw carefully.7 Close the front grille.8 Remove the terminal board cover on the side of the outdoor unit.t Each wire is labeled with the corresponding terminal number.The outdoor unit is powered from the indoor unit through the assembly cable.If the outdoor unit is more than 5 meters away from the indoor unit, you mustextend the cable. The maximum length of the cable is 15 (**09/12/18/19**) /20 (**24/25**) meters.Electrical work1) For electrical and earth works, comply with the ‘technical standards of electrical installations’ and the2) Tighten the terminal block screw to under 12kgf.cm.3) Precautions when connecting terminal blocks of the indoor unitBefore connecting, make sure the connecting part of the terminal socket is facing upwards.There must be no space between the terminal and the screw when connected.the ‘wiring regulations’ of the Electricity Enterprises Act.Upside down There is no ring terminalto cover the wire.The terminal socketis damaged.t For the terminal block wiring, use a wire with a ring terminal socket only.ng work.The terminal socket or there is a space between the screwand the ring terminal.is upside down.CAUTIONuuModel Power cable Interconnection cable3G, 1.0mm2 3G, 1.0mm2AS12**AS24/25**AS09**3G, 1.0mm 2 3G, 1.5mm2AS18/19AQ09**AQ18**AQ12**AQ24****3(M/C model name : AS19**SGE)G, 1.5mm23G, 2.5mm23G, 2.5mm23G, 2.5mm23G, 2.5mm23G, 1.0 mm H05VV-F3G, 1.0 mm H05VV-F5G, 1.5 mm H07RN-F5G, 1.0 mm H07RN-F5G, 1.5 mm H07RN-F3G, 1.5 mm H05VV-F3G, 2.5 mm H05VV-F 3G, 2.5 mm H07RN-F2 x 0.75 mm H05RN-F