ENGLISH33t The hose will be permanently into position after the installation and the gas leak test; refer to page37 for further details.t If you do not use the other drain hose hole, block it with a rubber stopper.t Make sure the installed direction of the drain hose is correct.Inadequate installation may cause condensate water leakage.t If the drain hose is routed inside the room, insulate the hose so that dripping condensation does not damage thet DO NOT WALL UP THE DRAIN HOSE CONNECTION !Drain hose connection must be easy accessible and serviceable.t Make sure the indoor unit is in upright position when you pour water to check for leakage.Change the direction only when it is necessary.1. Detach the rubber cap with the plier.2. Detach the drain hose by pulling it and turning to the left.3.hose and the outlet of the drain pan.4. Attach the rubber cap with a screwdriver by turning it to the right until it5. Check for leakage on both side of the drain outlet.1. If necessary, connect the 2-meter extension drain hose to the drain hose.2. If you use the extension drain hose, insulate the inside of the extension drain hose with a shield.3.tightly with a clamp.4. Pass the drain hose under the refrigerant pipe, keeping the drain hosetight.5. Pass the drain hose through the hole in the wall. Check if it slantsdownwards as seen in the picture.Drain hose installationDrain hose holeShieldDrain hose Extension drain hoseChanging direction of the drain hoseDrain hoseScrew holeScrewRubber capDrain pan outletPour the water in direction of arrow. h Direction of the drained water