4. TroubleshootingScan Area Adjustment• Diagnostics > Adjustment > Scan Area Adjustment > Automatic AdjustmentPurpose To correct image position and magnification of scanned images automatically.Operation Procedure 1) Locate the Scanner A/S Chart at the scan glass . Note that “Lead Edge” arrows need to headto the left side of scan glass and to be placed face down. Also note that the Scanner A/SCharts come in two sizes, A4 and Letter . Choose one size to meet your primary size of use.2) Press “OK” button. Automatic scanning will occur, and the system will automaticallycalculate the proper value based on scanning result of the chart .3) The new value set to the table.Verification 1) Scan the Scanner A/S Chart and send it to a PC. Scanning must be occur from the scan glass.2) To check the image position, compare the position of scale marks (a,b) of the chart tothe copy.3) To check the magnification, compare the length of line “c” of the chart to the copy.Specification a,b : 10, ± 1.5 mmc: 190, ± 1.5 mmReference A4 Scanner A/S ChartA4 S ca n n e r A/ S Ch a rtCopyright© 1995-2013 SAMSUNG. All rights reserved. 4-58