OfficeServ 7200 INSTALLATIONTECHNICAL MANUAL PART 7 MAY 20107.37WARNING: Do not attempt to connect commercial AC power to these contacts.1) After connecting a common bell, you must assign it in MMC 601 to a group as a ringdestination by using the code for common bell.2) After wiring to the contact pair, set contacts for continuous or steady operation.3) Next, program hunt group to include the common bell.4) Assign the trunk to ring the hunt group containing the common bell. Common bellcontrol can be used with station hunt groups, individual stations and universal answer.7.2.5 Ring Over PageWhen a customer-provided paging system is installed, incoming calls can be assigned to ringover page. Program the C.O. line or C.O. lines to ring a hunt group. Using MMC 601 assign theDN number of the Page Output (voice) for the MIS board being used as a member of thegroup or as the NEXT PORT for the overflow destination. Other stations may be assigned tothe same group to provide ringing to phones and the paging system at the same time.MISFUNCTION # in MMC 724DEFAULTDN03 37517.2.6 Connecting OfficeServ ManagerOfficeServ Manager (OSM) is a windows based computer application that providesmaintenance and management functions for the OfficeServ 7200.The minimum requirements for a PC running OfficeServ Manager (OSM) are as follows:Table 7.3 OfficeServ Manager SpecificationCategory SpecificationPlatform IBM PCCPU Pentium III or higherOS Windows 2000 or higherMain memory 64Mb or higherHard disk 1Gb or higherBeginning with system software version 4.14K technician must use OfficeServ InstallationTool.