OfficeServ 7200 INSTALLATIONTECHNICAL MANUAL PART 8 MAY 20108.23) Make sure the memory backup switch on MCP is in the OFF position for 60 secondsbefore putting it in the ON position.4) Turn on the power of the OfficeServ 7200 expansion cabinet first, then turn on thepower of the main cabinet.5) Check the LEDs of the MCP and LCP boards.6) The RUN LED of the MCP card lights green and the SM LED flashes when the systemnormally starts the booting process.7) Once the booting is complete, the RUN LED of the MCP board flashes green, and the SMLED stops flashing and remains steady GREEN. At this time the system created a defaultdatabase with the current hardware configuration and DIP switch settings of S3 on theMCP.8) The RUN LED of the LCP board flashes green when the power supply and processorstatus of the expansion rack is normal.If the Media Card is not detectedIf the system cannot detect the media card, the MC/SM LED of the MCP board mightnot light or flash. In such cases, turn off the power of the main cabinet, replace themedia card and turn the power on again. If the media card is still not detected, turnoff the power of the main cabinet and eject the MCP board.9) Check if the LED status of other interface boards are normal.10) If the LED status of the MCP, LCP, or interface board is abnormal, turn off the power ofthe cabinet and turn the power on again. If this does not restore normal systemoperation contact Samsung Technical Support.8.2.2 Starting the System with MP20The procedure for starting the OfficeServ 7200 system is as follows:1) Check if the boards and cables are properly mounted and connected to the OfficeServ7200 cabinet.2) Make sure the Secure Digital (SD) media card with the system software is in the MediaCard slot.3) Turn on the power of the OfficeServ 7200 expansion cabinet first, then turn on thepower of the main cabinet.4) After three minutes of RUN LED and SM LED activity, press the RESET SWITCH on thefaceplate of the MP20 processor card and hold it for 10 seconds. This will create a defaultdatabase with the current hardware configuration and DIP switch settings of S3 on theMP20.5) The RUN LED will change from GREEN to AMBER and will stop flashing after 10 seconds.Release the RESET button and wait 3 minutes for the system to boot into service.6) The RUN LED of the MP20 board lights green and the SM LED flashes when the systemnormally starts the booting process.