Defrost Control From 6 to 11 hrsDefrost Thermistor(502AT) 59℉(off)Electrical Rating AC115V 60Hz 11.6 AmpsMaximum Current Leakage 0.25 mAMaximum Ground Path Resistance 0.1OhmEnergy Consumption kWh/mo.Bimetal 104℉(on)/140℉(off)Ambient Temperature 70℉ 90℉Refrigerator,℉ 34�46 34�46Freezer,℉ -11�7 -11�7Run Time,% �40 �60Refrigerant Charge (R134a) 6.17 ozCompressor(MK183C-L2U) 1032 Btu/hrCompressor oil Freol α-15Capillary tube(Dia, Length) 0.033"",130""Dryer Molecular Sieve XH-9Clearance must be provided for air circulationAT TOP 1""AT SIDES 1/8""AT REAR 1""RS2530, RS2630PBA MAIN(RS2*11)∙∙∙∙∙∙∙∙∙∙DA41-00216APBA MAIN(RS2*21)∙∙∙∙∙∙∙∙∙∙DA41-00217BPBA MAIN(RS2*30) ∙∙∙∙∙∙∙∙∙DA41-00218CPBA MAIN(RS2*31) ∙∙∙∙∙∙∙∙∙DA41-00219DPBA PANEL(RS2*11)∙∙∙∙∙∙∙∙∙DA41-00218APBA PANEL(RS2*21)∙∙∙∙∙∙∙∙∙DA41-00218BPBA PANEL(RS2*30)∙∙∙∙∙∙∙∙∙DA41-00235APBA PANEL(RS2*31)∙∙∙∙∙∙∙∙∙DA41-00235BTRANS DC(115V/60Hz) ∙∙∙∙∙∙∙DA26-00022BTRANS DC(220V/50,60Hz)∙∙∙∙∙DA26-00022CTRANS DC(127V/60Hz) ∙∙∙∙∙∙∙DA26-00022DSENSOR(DEF SENSOR) ∙∙∙∙∙∙DA32-00006DSENSOR(F SENSOR) ∙∙∙∙∙∙∙∙DA32-00006DSENSOR(R SENSOR) ∙∙∙∙∙∙∙∙DA32-00006BSENSOR(ICE MAKER SENSOR)∙DA32-10108BRELAY ∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙∙DA35-10013QOVERLOADED REALY ∙∙∙∙∙∙∙DA35-10013DRUN CAPACITOR(12 ßfi)∙∙∙∙∙∙∙2501-001045FAN MOTOR(FREEZER) ∙∙∙∙∙∙DA31-00003WFAN MOTOR(UNIT)∙∙∙∙∙∙∙∙∙∙DA31-00103A4. SpecificationsCompressorDryerElectric boxSub-CondenserELECTRICAL SPECIFICATIONS Freezer RefrigeratorNO LOAD PERFORMANCEREFRIGERATION SYSTEMINSTALLATIONMODELSREPLACEMENT PARTS7