TROUBLE SHOOTING1) When the Power Freezer and the Lighting buttons(Freezer Temp and Child Lock buttoms for RSG5B*Model) are held down together for 6 seconds during the normal operation, the Fridge and Freezertemperature LEDs will blink for 2 seconds(4 seconds for RSG5B* Model) at an interval of 0.5 sec.2) At this time, when taking your fingers off the Power Freezer and the Lighting buttons(Freezer Tempand Child Lock buttoms for RSG5B* Model) and pressing the Fridge(Fridge Temp. for RSG5B* Model)button(sending out a "Ding-Dong" sound) it goes into the Load Status Display function.3) The Load Status Display mode shows the loads which MICOM sends out operational signals to.It only means that there are operational signals from MICOM. So, it does not indicate that thosesignalled loads are in operation. And, even though a specific part is displayed as in-operation, it maynot operate due to its own defect or the defective relay on PCB.4) The Load Status Display lasts for 30 seconds and it goes back to the normal operation mode.4-1-5) Load Status Display Function57When the Display Panel blinks for 2 seconds after pressing the Power Freezer and the Lightingbuttons for 6 seconds at the same time.Take your finger off from all the button and press the Fridge button.When the Display Panel blinks for 4 seconds at an interval of 0.5 second pressing theFreezer temp and the Child Lock buttons for 6 seconds at the same time.Take your finger off from all the button and press the Fridge button.RSG5K/F/D*RSG257*RSG5B*RSG5V*