18 EnglishMenu Setting ProceduresThe duration of alarm recording can be set separately for each camera. The DURATION (2) setting foreach camera that is made using the [ALARM DURATION SET] menu is effective when [DURATION] inthe [ALARM RECORDING] menu is set to “INDIV.” (See p. 16)1 Select the alarm recording duration for eachcamera from the menu.5 SEC, 10 SEC, 20 SEC, 40 SEC, 1 MIN, 2 MIN, 3 MIN,4 MIN, 5 MIN, 10 MIN, 15 MIN, CC(Default setting: 5 SEC)2 Click [SAVE] to set (or change) the alarmrecording durations for each camera.Screen example for DSR-3009 modelScreen example for DSR-3016 modelThis specifies the information to be displayed on the monitor by selecting “ON” or “OFF” in the menu.DATE (Default setting: ON)Current date or recording dateTIME (Default setting: ON)Current time or recording timeQUALITY (Default setting: ON)Quality of images being recorded or played backREC RATE (Default setting: OFF)Recording rate for images being recorded or playedbackALARM COUNT (Default setting: ON)Cumulative number of alarmsThe maximum count that can be displayed is 9999. If the countexceeds this number, it will be reset to 0.ALARM TYPE (Default setting: ON)Type of alarm recordingFor alarm recording: “ALARM” is displayed.For pre-alarm recording: “PRE” is displayed.Click [SAVE] to complete the DISPLAY SET menu settings (or changes) that are displayed on the screen.10. ALARM DURATION SET11. DISPLAY SETBecause this setting specifies the information to be displayed on the monitor that is connected to the main unit, it willhave no effect on the computer screen.